بدون مجموعه

ﺑﻪ ﻧﺎﻡ ﺧﺪﺍ

ﻳﻜﻲ ﺍﺯ ﻣﻮﺿﻮﻋﺎﺗﻲ ﻛﻪ ﺷﺮﻛﺖ ﺧﺪﻣﺎﺕ ﮔﻠﺪﻳﺮﺍﻥ ﺑﻪ ﻣﻨﻈﻮﺭ ﺧﺪﻣﺎﺕ ﺭﺳﺎﻧﻲ ﺑﻬﺘﺮ ﺑﻪ ﻣﺸﺘﺮﻳﺎﻥ ﺧﻮﺩ ﻭ ﺟﻠﻮﮔﻴﺮﻱ ﺍﺯ ﺗﻌﺪﺩ ﺗﻌﻤﻴﺮ ﺑﻪ ﺁﻥ ﺗﻮﺟﻪ ﻭﻳﮋﻩ ﺩﺍﺭﺩ، ﺗﺸﺨﻴﺺ ﺑﻪ ﻣﻮﻗﻊ ﺧﻄﺎ، ﺭﻓﻊ ﺍﻳﺮﺍﺩ  ﻭ ﺍﻧﺠﺎﻡ ﺗﻌﻤﻴﺮﺍﺕ ﻛﺎﻣﻞ ﻭ ﺻﺤﻴﺢ ﺩﺳﺘﮕﺎﻩ ﻫﺎ ﻣﻲ ﺑﺎﺷﺪ .ﺑﻪ ﻃﻮﺭﻱ ﻛﻪ ﻣﺠﺪﺩﺍ ﺩﺭ ﺑﺎﺯﻩ ﺯﻣﺎﻧﻲ ﻛﻮﺗﺎﻫﻲ ﺩﭼﺎﺭ ﻣﺸﻜﻞ ﻗﺒﻠﻲ  ﻧﺸﻮﻧﺪ  .

 ، ﺗﺸﺮﻳﺢ ﺁﻥ ﻫﺎ، ﻃﺮﻳﻘﻪ ﻱ ﺭﻓﻊ INVERTERﻟﺬﺍ ﺍﻳﻦ ﻛﺘﺎﺑﭽﻪ ﺷﺎﻣﻞ ﻛﻠﻴﻪ ﻱ ﻛﺪ  ﺧﻄﺎﻫﺎﻱ ﺍﺣﺘﻤﺎﻟﻲ ﺩﺳﺘﮕﺎﻩ ﻫﺎﻱ ﺍﺭﻭﺭﻫﺎ ﻭ ﺭﻭﺵ ﻫﺎﻱ ﺑﺮﺭﺳﻲ ﺩﺳﺘﮕﺎﻩ ﻭ ﻫﻤﭽﻨﻴﻦ ﻃﺮﻳﻘﻪ ﺍﺭﻭﺭ ﻳﺎﺑﻲ  ﻣﻲ ﺑﺎﺷﺪ  .ﺑﻪ ﺍﻣﻴﺪ ﺁﻧﻜﻪ ﺑﺎ ﻫﻤﻜﺎﺭﻱ ﺗﻤﺎﻡ ﺍﻋﻀﺎﻱ ﺧﺎﻧﻮﺍﺩﻩ ﮔﻠﺪﻳﺮﺍﻥ ، ﺭﻭﺯ ﺑﻪ ﺭﻭﺯ ﺷﺎﻫﺪ ﭘﻴﺸﺮﻓﺖ ﺑﺎﺷﻴﻢ .

ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

ﻓﻬﺮﺳﺖ :

 1 .....................................................................................................................ﻛﺪ ﺧﻄﺎﻫﺎ ﻭ ﺗﻮﺿﻴﺤﺎﺕ ﺁﻧﻬﺎ

............................................................................................................. –ﺭﻓﻊ ﺍﻳﺮﺍﺩ  5 ﺧﻄﺎﻫﺎﻱ ﻭﺍﺣﺪ ﺩﺍﺧﻠﻲ

CH01 ﺧﻄﺎﻫﺎﻱ - CH02 - CH06 - CH12 ........................................................................................ 5

CH53 ﺧﻄﺎﻱ – CH05.......................................................................................................................... 7

 9 ......................................................................................................................................... CH10ﺧﻄﺎﻱ

 10 ....................................................................................................................................... CH21ﺧﻄﺎﻱ

 11 ....................................................................................................................................... CH22ﺧﻄﺎﻱ

 15 ....................................................................................................................................... CH26ﺧﻄﺎﻱ

 22 ....................................................................................................................................... CH27ﺧﻄﺎﻱ

 26 ....................................................................................................................................... CH29ﺧﻄﺎﻱ

 30 ....................................................................................................................................... CH32ﺧﻄﺎﻱ

  30 ....................................................................................................................................... CH40ﺧﻄﺎﻱ

CH41 ﺧﻄﺎﻱ – CH44 – CH45 – CH46 – CH47 – CH65  .................................................... 38

 .................................................................................................................. –ﺧﻄﺎﻱ ﺟﺪﻭﻝ ﺩﻣﺎ  42 ﻣﻘﺎﻭﻣﺖ

 44 ....................................................................................................................................... CH53ﺧﻄﺎﻱ

 46 ....................................................................................................................................... CH60ﺧﻄﺎﻱ

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 2

 

 47 ....................................................................................................................................... CH61ﺧﻄﺎﻱ

 49 ....................................................................................................................................... CH62ﺧﻄﺎﻱ

 52 ....................................................................................................................................... CH67ﺧﻄﺎﻱ

 55 ...........................................................................................ﭼﮕﻮﻧﮕﻲ ﺑﺮﺭﺳﻲ ﺷﺮﺍﻳﻂ ﻧﺼﺐ ﻭﺍﺣﺪ ﺑﻴﺮﻭﻧﻲ

 56 .................................................................................................................ﭼﮕﻮﻧﮕﻲ ﺑﺮﺭﺳﻲ ﺟﺮﻳﺎﻥ ﻣﺒﺮﺩ

 57 ........................................................................................................................ EEVﺭﻭﺵ ﭼﻚ ﻛﺮﺩﻥ

 58 ...........................................................................................ﭼﮕﻮﻧﮕﻲ ﺑﺮﺭﺳﻲ ﻣﻘﺎﻭﻣﺖ ﻓﺎﺯﻫﺎﻱ ﻛﻤﭙﺮﺳﻮﺭ

 60 ...............................................................................................................IPMﭼﮕﻮﻧﮕﻲ ﺑﺮﺭﺳﻲ ﻗﺴﻤﺖ

 62 .........................................................................................ﺑﺮﺭﺳﻲ ﻣﺪﺍﺭ ﺁﺷﻜﺎﺭ ﺳﺎﺯ ﺟﺮﻳﺎﻥ ﻓﺎﺯ ﻛﻤﭙﺮﺳﻮﺭ

 64 ............................................................................................ﺑﺮﺭﺳﻲ ﻣﺪﺍﺭ ﺁﺷﻜﺎﺭ ﺳﺎﺯ ﺟﺮﻳﺎﻥ ﻓﺎﺯ ﻭﺭﻭﺩﻱ

 ................................................................................................................. 4ﭼﮕﻮﻧﮕﻲ ﺑﺮﺭﺳﻲ ﺷﻴﺮ  65 ﻃﺮﻓﻪ

 ...... ................................................................................................. 4ﺑﺮﺭﺳﻲ ﻣﻘﺎﻭﻣﺖ ﻛﻮﻳﻞ ﺷﻴﺮ  66 ﻃﺮﻓﻪ 

 67 ................................................................................................................... EEVﭼﮕﻮﻧﮕﻲ ﺑﺮﺭﺳﻲ ﺷﻴﺮ

 

 

 

 

3

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

ﻛﺪ ﺧﻄﺎ ﻫﺎ ﻭ ﺗﻮﺿﻴﺤﺎﺕ ﺁﻧﻬﺎ 

  ﻧﺸﺎﻧﮕﺮ ﺧﻄﺎ ■

 ﺍﻳﻦ ﻋﻤﻠﻜﺮﺩ ﺑﺮﺍﻱ ﺗﺸﺨﻴﺺ ﺍﻳﺮﺍﺩ ﻭ ﻧﺸﺎﻥ ﺩﺍﺩﻥ ﺁﻥ ﺩﺭ ﺻﻔﺤﻪ ﺩﻳﺴﭙﻠﻲ ﻣﻲ ﺑﺎﺷﺪ• .   . ﺍﮔﺮ ﻫﻤﺰﻣﺎﻥ ﺩﻭ ﺧﻄﺎ ﺩﺍﺷﺘﻪ ﺑﺎﺷﻴﻢ ﺩﺭ ﺍﺑﺘﺪﺍ ﺧﻄﺎﻱﻱ ﻛﻪ ﺧﻄﺮﻧﺎﻙ ﺗﺮ ﺍﺳﺖ ﻧﻤﺎﻳﺶ ﺩﺍﺩﻩ ﻣﻲ ﺷﻮﺩ • . ﺑﻪ ﺻﻮﺭﺕ ﻧﺮﻣﺎﻝ ﺷﺮﻭﻉ ﺑﻪ ﭼﺸﻤﻚ ﺯﺩﻥ ﻣﻲ ﻛﻨﺪLED ﺑﻌﺪ ﺍﺯ ﻭﻗﻮﻉ ﺧﻄﺎ ﺍﮔﺮ ﺍﻳﺮﺍﺩ ﺭﻓﻊ ﮔﺮﺩﺩ • • . ﭘﺲ ﺍﺯ ﺑﺮﻃﺮﻑ ﻛﺮﺩﻥ ﺧﻄﺎ ﺑﺮﻕ ﺭﺍ ﻗﻄﻊ ﻭ ﺳﭙﺲ ﺩﻭﺑﺎﺭﻩ ﻭﺻﻞ ﻛﻨﻴﺪ 

ﺗﻮﺿﻴﺤﺎﺕ ■   ﺧﻄﺎ ﺩﺭ ﻭﺍﺣﺪ ﺩﺍﺧﻠﻲ 

ﻛﺪ   ﺧﻄﺎ

 ﺗﻮﺿﻴﺤﺎﺕ

 

ﻧﺸﺎﻧﻪ ﺧﻄﺎ

   ﻭﺍﺣﺪ ﺩﺍﺧﻠﻲ LED1(  )ﺳﺒﺰ LED2  )ﻗﺮﻣﺰ(

1 ﺳﻨﺴﻮﺭ ﻫﻮﺍﻱ ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ ﺑﺎﺯ  /ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ  1 -ﺑﺎﺭ

 2 ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ ﻭﺭﻭﺩﻱ ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ ﺑﺎﺯ  /ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ    ﺑﺎﺭ2

 5 ﺧﻄﺎﻱ ﺍﺭﺗﺒﺎﻃﻲ ﺑﻴﻦ ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ ﻭ ﻳﻮﻧﻴﺖ ﺑﻴﺮﻭﻧﻲ    ﺑﺎﺭ5

 6 ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ ﺧﺮﻭﺟﻲ ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ  6 - ﺑﺎﺭ

 

9 EEPROM   ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ 9 - ﺑﺎﺭ

 10 ﺍﻳﺮﺍﺩ ﻋﻤﻠﻜﺮﺩ ﻣﻮﺗﻮﺭ ﻓﻦ ﺩﺍﺧﻠﻲ   1 ﺑﺎﺭ 12 ﺳﻨﺴﻮﺭ ﻭﺳﻂ ﻟﻮﻟﻪ ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ  2  ﺑﺎﺭ 1 ﺑﺎﺭ

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 4

 

SB/SC Chassis (Art cool)           SB/SC Chassis (Libero)  

 

 

 

 

 

 

 

 

 : ﺩﺭ ﺩﺳﺘﮕﺎﻫﻬﺎﻱ ﻛﻪ ﻧﻤﺎﻳﺸﮕﺮ ﺳﻮﻥ ﺳﮕﻤﻨﺖ ﺩﺍﺭﻧﺪ ﺑﻪ ﺻﻮﺭﺕ ﻋﺪﺩﻱ ﻇﺎﻫﺮ ﻣﻲ ﺷﻮﺩ   ﻣﺜﺎﻝ : . CH 05 ﺧﻄﺎﻱ ﺍﺭﺗﺒﺎﻃﻲ ﺑﺎ ﻇﺎﻫﺮ ﻣﻲ ﺷﻮﺩ

 

ﻣﺤﻞ ﻗﺮﺍﺭ ﮔﻴﺮﻱ    ﺩﺭ ﺑﺮﺩ ﻭﺍﺣﺪ ﺑﻴﺮﻭﻧﻲ LED

 

 

  ﻳﻜﺎﻥpowerﭼﺮﺍﻍ  ﺩﻫﮕﺎﻥ plasmaﭼﺮﺍﻍ

4kw Controller(UE,UE1)   ﺩﺍﺭLED 2ﻧﻮﻉ

5

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

 

                     

 

   ﺩﺍﺭLED  2ﻧﻮﻉ

 

 

 

2kw Controller(UL,UL2)   ﺩﺍﺭLED 2ﻧﻮﻉ

1.5kw Controller(UA3)   ﺩﺍﺭLED 2ﻧﻮﻉ

   ﺳﺒﺰ ﻳﻜﺎﻥ LED 1

 ﻗﺮﻣﺰ ﺩﻫﮕﺎﻥLED 2 

ﻭﻟﺘﺎژ 21 ﻣﺜﺎﻝ ( ﺧﻄﺎﻱ ) DC( ﺑﺎﻻ

 

   ﺩﺍﺭLED 1ﻧﻮﻉ

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 6

 

ﺗﻮﺿﻴﺤﺎﺕ  ﺍﺭﻭﺭﻫﺎ

 

 

 

 

 

 

 

ﺧﻄﺎﻫﺎﻱ ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ

ﺧﻄﺎﻫﺎﻱ ﻳﻮﻧﻴﺖ ﺑﻴﺮﻭﻧﻲ

7

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

  ﺧﻄﺎﻫﺎﻱ ﻭﺍﺣﺪ ﺩﺍﺧﻠﻲ –ﺭﻓﻊ ﺍﻳﺮﺍﺩ  CH01, CH02, CH06,CH12 ﺧﻄﺎﻫﺎﻱ

ﻧﻘﺎﻁ   ﺑﺮﺭﺳﻲ ﻋﻠﺖ ﺧﻄﺎ  ﻋﻨﻮﺍﻥ  ﻛﺪ ﺧﻄﺎ 

  ﺳﻨﺴﻮﺭ ﻫﻮﺍﻱ ﺩﺍﺧﻠﻲ CH01 

ﺍﺗﺼﺎﻝ ﻧﺎﺩﺭﺳﺖ ﻳﺎ ﺑﺎﺯ  / ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﺑﻮﺩﻥ ﺳﻨﺴﻮﺭ

ﻭﺿﻌﻴﺖ ﺍﺗﺼﺎﻝ ﺳﻨﺴﻮﺭ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ  : 10 ﻣﻘﺎﻭﻣﺖ ﻧﺮﻣﺎﻝ ㏀ /at 25℃(77℉)

  ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ ﻭﺭﻭﺩﻱ ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ CH02

ﺍﺗﺼﺎﻝ ﻧﺎﺩﺭﺳﺖ ﻳﺎ ﺑﺎﺯ  / ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﺑﻮﺩﻥ ﺳﻨﺴﻮﺭ

ﻭﺿﻌﻴﺖ ﺍﺗﺼﺎﻝ ﺳﻨﺴﻮﺭ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ  : 5 ﻣﻘﺎﻭﻣﺖ ﻧﺮﻣﺎﻝ ㏀ /at 25℃(77℉)

  ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ ﺧﺮﻭﺟﻲ ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ CH06

  / ﺍﺗﺼﺎﻝ ﻧﺎﺩﺭﺳﺖ ﻳﺎ ﺑﺎﺯ ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﺑﻮﺩﻥ ﺳﻨﺴﻮﺭ

ﻭﺿﻌﻴﺖ ﺍﺗﺼﺎﻝ ﺳﻨﺴﻮﺭ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ  : 5 ﻣﻘﺎﻭﻣﺖ ﻧﺮﻣﺎﻝ ㏀ /at 25℃(77℉)

  ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ ﻭﺳﻂ ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ CH12

ﺍﺗﺼﺎﻝ ﻧﺎﺩﺭﺳﺖ ﻳﺎ ﺑﺎﺯ  / ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﺑﻮﺩﻥ ﺳﻨﺴﻮﺭ

ﻭﺿﻌﻴﺖ ﺍﺗﺼﺎﻝ ﺳﻨﺴﻮﺭ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ  : 5 ﻣﻘﺎﻭﻣﺖ ﻧﺮﻣﺎﻝ ㏀ /at 25℃(77℉) 

ﻭﺿﻌﻴﺖ ﺍﺗﺼﺎﻝ ﺳﻨﺴﻮﺭ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ 1 - 

ﺑﻌﺪ ﺍﺯ ﺟﺪﺍ ﻛﺮﺩﻥ ﺳﻨﺴﻮﺭ ﺍﺯ ﺑﺮﺩ ﻣﻘﺎﻭﻣﺖ ﺁﻥ ﺭﺍ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻛﻨﻴﺪ 2 -

ﺍﮔﺮ ﻣﻘﺎﻭﻣﺖ 3   ﻳﺎ ﺑﻴﻨﻬﺎﻳﺖ ﺑﻮﺩ ﺳﻨﺴﻮﺭ ﺭﺍ ﺗﻌﻮﻳﺾ ﻛﻨﻴﺪ0

ﺍﮔﺮ ﻣﻘﺎﻭﻣﺖ ﻧﺮﻣﺎﻝ ﺑﻮﺩ ﺑﺮﺩ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ 4 - 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 8

 

ﻣﺤﻞ ﻗﺮﺍﺭﮔﻴﺮﻱ ﺳﻨﺴﻮﺭﻫﺎ :  

 

 

ﺭﻭﺵ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ :  ﻛﺎﻧﻜﺘﻮﺭ ﺭﺍ ﺍﺯ ﺭﻭﻱ ﺑﺮﺩ ﺟﺪﺍ ﻛﻨﻴﺪ .  .  ﻗﺮﺍﺭ ﺩﻫﻴﺪΩﺭﻧﺞ ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﺍﻫﻢ ﻣﻘﺎﻭﻣﺖ ﻛﺎﻧﻜﺘﻮﺭ ﺭﺍ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻛﻨﻴﺪ .

 

 

 

 

 ﺍﻫﻢ ﻣﺘﺮ

 ﻟﻮﻟﻪ ﻣﺎﻳﻊ

 ﺍﻭﺍﭘﺮﺍﺗﻮﺭ

 ﻟﻮﻟﻪ ﮔﺎﺯ

ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ ﻭﺭﻭﺩﻱ

 

ﺳﻨﺴﻮﺭ ﻭﺭﻭﺩﻱ

 ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ ﺧﺮﻭﺟﻲ

 

ﺳﻨﺴﻮﺭ ﻫﻮﺍﻱ ﻣﺤﻴﻂ

 

 ﻛﺎﻧﻜﺘﻮﺭ ﺳﻨﺴﻮﺭ

9

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

  ﻣﻘﺎﻭﻣﺖ ﻧﺎﻡ ﺳﻨﺴﻮﺭ  ﺭﻧﮓ ﻛﺎﻧﻜﺘﻮﺭ  ﻧﺸﺎﻧﻪ  ﺳﻨﺴﻮﺭ ﻫﻮﺍﻱ ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ  ﺳﻔﻴﺪ 10kΩ at 25 °C   TH1 ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ ﻭﺭﻭﺩﻱ ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ 5kΩ at 25 °C   

5kΩ at 25 °C

ﺳﻨﺴﻮﺭ ﺧﺮﻭﺟﻲ ﻟﻮﻟﻪ ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ  ﻗﺮﻣﺰ  TH2

 ﺳﻨﺴﻮﺭ ﻭﺳﻂ ﻟﻮﻟﻪ ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ  ﺳﻔﻴﺪ 5kΩ at 25 °C   TH3

 

 

 CH05, CH53ﻛﺪ ﺧﻄﺎﻱ  )ﺧﻄﺎﻱ ﺍﺭﺗﺒﺎﻃﻲ(

ﻧﻘﺎﻁ   ﺑﺮﺭﺳﻲ ﻋﻠﺖ ﺧﻄﺎ  ﻋﻨﻮﺍﻥ  ﻛﺪ ﺧﻄﺎ 

CH05 / 53

    ﺍﺭﺗﺒﺎﻃﻲ ) ﺑﻴﻦ ﻭﺍﺣﺪ ﺩﺍﺧﻠﻲ ﻭ ﺑﻴﺮﻭﻧﻲ( 

ﻗﻄﻊ ﻳﺎ ﻣﺨﺘﻞ ﺷﺪﻥ ﺍﺭﺗﺒﺎﻁ ﺑﻴﻦ ﻭﺍﺣﺪ ﺩﺍﺧﻠﻲ ﻭ ﺑﻴﺮﻭﻧﻲ    ﺩﻗﻴﻘﻪ3ﺑﻴﺶ ﺍﺯ

ﻭﻟﺘﺎژ ﻭﺭﻭﺩﻱ ﻧﺎﻣﻨﺎﺳﺐ /ﺑﻴﺮﻭﻥ ﺍﺯ ﻣﺤﺪﻭﺩﻩ   230 ﺍﻟﻲ 208 ﺍﺗﺼﺎﻝ ﻧﺎﺩﺭﺳﺖ ﻛﺎﻧﻜﺘﻮﺭﻫﺎﻱ ﺍﺭﺗﺒﺎﻃﻲ  ﻗﻄﻊ ﺷﺪﮔﻲ ﺳﻴﻢ ﻫﺎﻱ ﺍﺭﺗﺒﺎﻃﻲ  ﺍﺗﺼﺎﻝ ﻧﺎﺩﺭﺳﺖ ﺯﻣﻴﻦ )ﺍﺭﺕ( ﺑﻴﻦ ﻭﺍﺣﺪ ﺩﺍﺧﻠﻲ ﻭ ﺑﻴﺮﻭﻧﻲ  ﺍﺗﺼﺎﻝ ﻧﺎﺩﺭﺳﺖ ﺍﺭﺕ ﻣﺤﻞ ﺑﺎ ﺩﺳﺘﮕﺎﻩ ﺑﻴﺮﻭﻧﻲ  ﻣﺪﺍﺭ ﺍﻧﺘﻘﺎﻟﻲ ﺑﺮﺩ ﻭﺍﺣﺪ ﺑﻴﺮﻭﻧﻲ ﺍﻳﺮﺍﺩ ﺩﺍﺭﺩ  ﻣﺪﺍﺭ ﺍﻧﺘﻘﺎﻟﻲ ﺑﺮﺩ ﻭﺍﺣﺪ ﺩﺍﺧﻠﻲ ﺍﻳﺮﺍﺩ ﺩﺍﺭﺩ  ﺧﺮﺍﺑﻲ ﺭﺍﻛﺘﻮﺭ ﻳﻮﻧﻴﺖ ﺑﻴﺮﻭﻧﻲ ﻧﺰﺩﻳﻚ ﺑﺮﻕ ﻓﺸﺎﺭ ﻗﻮﻱ ﺑﺎﺷﺪ ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ ﻧﺰﺩﻳﻚ ﺗﺎﺑﻠﻮ ﺑﺮﻕ ﻧﺼﺐ ﺷﺪﻩ ﺑﺎﺷﺪ ﻓﻴﻮﺯ ﻫﺎﻱ ﺭﻭﻱ ﺑﺮﺩ ﺳﻮﺧﺘﻪ ﺑﺎﺷﻨﺪ 

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 10

 

 ﺩﺭ ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ ﻧﻤﺎﻳﺶ ﺩﺍﺩﻩ ﻣﻲ ﺷﻮﺩ ﻭ CH05*  ﺩﺭ ﻳﻮﻧﻴﺖ ﺑﻴﺮﻭﻧﻲ ﻧﻤﺎﻳﺶ ﺩﺍﺩﻩ ﻣﻲ CH53 ﺷﻮﺩ.*  ﻭﻟﺘﺎژ ﺑﻴﻦ 1 ( 230 ﺍﻟﻲ 208 ) .ﻭﻟﺘﺎژ ﻭﺭﻭﺩﻱ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ  ﺑﺎﺷﺪ .  ﺳﻴﻢ ﺍﺭﺗﺒﺎﻃﻲ ﺑﻪ ﺩﺭﺳﺘﻲ ﻭﺻﻞ ﺷﺪﻩ ﺑﺎﺷﺪ 2 ..  .  ﺗﺮﻣﻴﻢ ﻳﺎ ﺗﻌﻮﻳﺾ ﺳﻴﻢ ﺍﺭﺗﺒﺎﻃﻲ →   .  ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ ﺳﻴﻢ ﻧﻮﻝ ﺍﺗﺼﺎﻝ ﺩﺍﺷﺘﻪ ﺑﺎﺷﺪ →   3 : 2 .ﻣﻘﺎﻭﻣﺖ ﺑﻴﻦ ﺳﻴﻢ ﺍﺭﺗﺒﺎﻃﻲ ﻭ ﺯﻣﻴﻦ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ  ﻧﺮﻣﺎﻝ: ﺑﻴﺶ ﺍﺯ ㏁)(  ﺳﻴﻢ ﻫﺎﻱ ﺍﺭﺗﺒﺎﻃﻲ ﺑﻪ ﺩﺭﺳﺘﻲ ﺑﻪ ﻛﺎﻧﻜﺘﻮﺭﻫﺎ ﻭﺻﻞ ﺷﺪﻩ ﺑﺎﺷﻨﺪ 4 .. ﻭﺿﻌﻴﺖ ﺍﺗﺼﺎﻝ ﺍﺭﺕ ﺑﻴﻦ ﻭﺍﺣﺪ ﺩﺍﺧﻠﻲ ﻭ ﻭﺍﺣﺪ ﺑﻴﺮﻭﻧﻲ ﻭ ﻫﻤﭽﻨﻴﻦ ﻭﺍﺣﺪ ﺑﻴﺮﻭﻧﻲ ﺑﺎ ﺍﺭﺕ ﻣﺤﻞ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ 5 .. ﺗﺮﻣﻴﻨﺎﻝ ﺷﻤﺎﺭﻩ 6 ﺍﺳﺘﻔﺎﺩﻩ 3 ) .ﻭﺿﻌﻴﺖ ﻭﺟﻮﺩ ﻛﺎﺑﻞ ﺷﻴﻠﺪ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ)ﻛﺎﺑﻞ ﺷﻴﻠﺪ ﺗﻨﻬﺎ ﺑﺎﻳﺪ ﺑﺮﺍﻱ ﻣﺴﻴﺮﺳﻴﮕﻨﺎﻝ  ( ﺷﺪﻩ ﺑﺎﺷﺪ(. ﻣﺤﻞ ﻧﺼﺐ ﻳﻮﻧﻴﺖ ﺑﻴﺮﻭﻧﻲ ﻧﺒﺎﻳﺪ ﻧﺰﺩﻳﻚ ﺑﻪ ﺑﺮﻕ ﻓﺸﺎﺭ ﻗﻮﻱ ﻳﺎ ﻛﻨﺘﻮﺭ ﻭ ﺗﺎﺑﻠﻮ ﺑﺮﻕ 7 .3. ﻓﺎﺯ ﺑﺎﺷﺪ

 

ﺩﺭ ﺗﻤﺎﻣﻲ ﺍﺭﻭﺭﻫﺎ:

ﺯﻣﺎﻧﻲ ﻛﻪ ﻫﻤﻪ ﻣﺮﺍﺣﻞ ﺑﺮﺭﺳﻲ ﺍﻧﺠﺎﻡ ﺷﺪ ﻭ ﺑﻪ ﺍﻳﻦ ﻧﺘﻴﺠﻪ ﺭﺳﻴﺪﻳﺪ ﻛﻪ ﺑﺮﺩ ﺭﺍ ﺗﻌﻮﻳﺾ ﻛﻨﻴﺪ , ﻗﺒﻞ ﺍﺯ ﺗﻌﻮﻳﺾ ﺑﺮﺩ ﺍﻗﺪﺍﻣﺎﺕ ﺯﻳﺮ ﺭﺍ ﺣﺘﻤﺎ ﺍﻧﺠﺎﻡ ﺩﻫﻴﺪ :  1 (ﺑﺮﻕ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﻗﻄﻊ ﻛﻨﻴﺪ 2 (ﺗﻤﺎﻣﻲ ﻛﺎﻧﻜﺘﻮﺭﻫﺎﻱ ﺑﺮﺩ ﺑﻴﺮﻭﻧﻲ ﻭ ﺑﺮﺩ ﺩﺍﺧﻠﻲ ﺭﺍ ﺍﺯ ﺭﻭﻱ ﺑﺮﺩ ﺟﺪﺍ ﻛﻨﻴﺪ 3 (ﭼﻨﺪ ﺩﻗﻴﻘﻪ ﺻﺒﺮ ﻛﻨﻴﺪ 4 (ﺳﭙﺲ ﺗﻤﺎﻣﻲ ﻛﺎﻧﻜﺘﻮﺭ ﻫﺎ ﺭﺍ ﺩﻭﺑﺎﺭﻩ ﻭﺻﻞ ﻛﻨﻴﺪ 5 (. ﺑﺮﻕ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﺩﻭﺑﺎﺭﻩ ﻭﺻﻞ ﻛﻨﻴﺪ ﻭ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﺭﻭﺷﻦ ﻛﻨﻴﺪ ﺩﺭ ﺻﻮﺭﺕ ﺑﺮﻭﺯ ﺩﻭﺑﺎﺭﻩ ﺍﺭﻭﺭ ﻧﺴﺒﺖ ﺑﻪ ﺗﻌﻮﻳﺾ ﺑﺮﺩ ﺍﻗﺪﺍﻡ ﻧﻤﺎﺋﻴﺪ.

 

 

 

11

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

( CH09ﺧﻄﺎﻱ  )ﺧﻄﺎﻱ ﺑﺮﺩ ﺁﭘﺸﻦ 

  ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ ﻋﻠﺖ ﺧﻄﺎ  ﻋﻨﻮﺍﻥ  ﻛﺪ ﺧﻄﺎ  ﻭﺿﻌﻴﺖ ﺍﺗﺼﺎﻝ ﺑﺮﺩ ﺁﭘﺸﻦ ﺭﺍ ﺑﺮﺭﺳﻲ   ﻛﻨﻴﺪ ﺍﺗﺼﺎﻝ ﻧﺎﺩﺭﺳﺖ ﺑﺮﺩ ﺁﭘﺸﻦ ﻳﺎ ﺍﻳﺮﺍﺩ ﺍﺯ ﺑﺮﺩ ﺁﭘﺸﻦ  CH09  ﺧﻄﺎﻱ ﺑﺮﺩ ﺁﭘﺸﻦ

 

 

ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ ﺑﺮﺩ ﺁﭘﺸﻦ ﺑﻪ ﺩﺭﺳﺘﻲ ﺍﺗﺼﺎﻝ ﺩﺍﺷﺘﻪ ﺑﺎﺷﺪ 1 . 

 

 

 

 

 

 

 

 

 

 

 

ﻣﻲ ﺑﺎﺷﺪ ﺩﻳﺪﻩ ﺷﺪﻩ 88)ﺩﺭ ﺑﺮﺧﻲ ﻣﻮﺍﺭﺩ ﺩﺭ ﻣﺪﻝ ﻫﺎﻳﻲ ﻛﻪ ﺩﻳﺴﭙﻠﻲ ﺁﻧﻬﺎ ﺳﻮﻥ ﺳﮕﻤﻨﺘﻲ  ( ﻛﻪ ﺍﻋﺪﺍﺩ ﺑﺮ ﺭﻭﻱ ﺩﻳﺴﭙﻠﻲ ﺑﻪ ﺻﻮﺭﺕ ﻧﺎﺧﻮﺍﻧﺎ ﻭ ﺩﺭﻫﻢ ﻇﺎﻫﺮ ﻣﻲ ﺷﻮﻧﺪ  .ﻋﻠﺖ ﺍﻳﻦ ﺍﻳﺮﺍﺩ  ﺍﺳﺖ ﺑﺮﺩ ﺩﻳﺴﭙﻠﻲ ﻳﺎ ﺑﺮﺩ ﺁﭘﺸﻦ ﺑﺎﺷﺪ ﻛﻪ ﺣﺘﻤﺎ ﺑﻌﺪ ﺍﺯ ﺗﻌﻮﻳﺾ ﺍﻳﻦ ﻗﻄﻌﺎﺕ ﺑﺎﻳﺪ ﺑﺮﻕ  ﻣﻤﻜﻦ  ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﺭﻳﺴﺖ ﻛﻨﻴﺪ .

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 12

 

( CH10ﻛﺪ ﺧﻄﺎﻱ  )ﻣﻮﺗﻮﺭ ﻓﻦ ﺩﺍﺧﻠﻲ 

  ﻛﺪ ﺧﻄﺎ ﻋﻨﻮﺍﻥ  ﻋﻠﺖ ﺧﻄﺎ  ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ

 

CH10

ﺍﻳﺮﺍﺩ ﻣﻮﺗﻮﺭ ﻓﻦ   ﺩﺍﺧﻠﻲ

 1ﺍﮔﺮ ﻣﻮﺗﻮﺭ ﻓﻦ ﺑﻌﺪ ﺍﺯ ﺩﻗﻴﻘﻪ ﺍﺯ ﻋﻤﻠﻴﺎﺕ ﺍﻭﻟﻴﻪ ﺑﻪ ﻛﺎﺭﻧﻴﺎﻓﺘﺪ 

  • ﻗﻔﻞ ﺷﺪﻥ ﻣﻮﺗﻮﺭ ﻓﻦ •  ﺍﺭﺗﺒﺎﻁ ﻧﺎﺩﺭﺳﺖ ﺳﻴﻢ ﻫﺎﻱ ﻣﻮﺗﻮﺭﻓﻦ ﺑﺎ ﺑﺮﺩ •  ﻣﻮﺗﻮﺭ ﻓﻦ ﺍﻳﺮﺍﺩ ﺩﺍﺭﺩ •  ) PCBﺍﻳﺮﺍﺩ ﺑﺮﺩ ( ﺩﺍﺧﻠﻲ 

 

  ﺭﻓﻊ ﺍﻳﺮﺍﺩ ﺗﺎﺋﻴﺪ ﻭ   ﺑﺮﺭﺳﻲ ﻋﻠﺖ ﺧﻄﺎ 

  ﻧﻮﻉ ﺍﻳﺮﺍﺩ )ﺑﺮﺭﺳﻲ ﻧﺤﻮﻩ   ﻋﻤﻠﻜﺮﺩ (

  ﻛﺪ ﺧﻄﺎ

ﺍﺻﻼﺡ ﻳﺎ ﺗﻌﻮﻳﺾ ﻣﻮﺗﻮﺭ   ﻓﻦ

ﺷﻔﺖ ﻣﻮﺗﻮﺭ ﺭﺍ ﺑﺎ ﺩﺳﺖ ﺑﭽﺮﺧﺎﻧﻴﺪ ﺍﮔﺮ ﮔﺮﺩﺵ ﻏﻴﺮ ﻋﺎﺩﻱ ﺑﺎﺷﺪ ﺍﻳﺮﺍﺩ   ﺩﺍﺭﺩ

ﻓﻦ ﺗﻮﺳﻂ ﻗﻄﻌﻪ ﺩﻳﮕﺮﻱ ﮔﻴﺮ   ﻛﺮﺩﻩ ﻳﺎ ﻓﻦ ﻣﺸﻜﻞ ﭘﻴﺪﺍ ﻛﺮﺩﻩ

ﻗﻔﻞ ﺷﺪﻥ ﺳﺎﺧﺘﺎﺭﻣﻮﺗﻮﺭ ﻓﻦ ﺩﺍﺧﻠﻲ 

CH10

ﺗﻌﻤﻴﺮ ﺳﻴﻢ ﻫﺎ ﻳﺎ ﺗﻌﻮﻳﺾ ﻣﻮﺗﻮﺭ  ﻓﻦ

ﺑﺮﺭﺳﻲ ﺩﻳﺪﺍﺭﻱ  ﺷﻮﺩ

 ﻛﺎﻧﻜﺘﻮﺭ ﻣﻮﺗﻮﺭ ﻓﻦ ﻗﻄﻊ • ﺷﺪﻩ   ﺗﺮﻣﻴﻨﺎﻝ ﺛﺎﺑﺖ ﺍﻳﺮﺍﺩ ﭘﻴﺪﺍ • ﻛﺮﺩﻩ  •  ﺳﻴﻢ ﻫﺎ ﻗﻄﻊ ﺷﺪﻩ ﻳﺎ ﻟﻪ ﺷﺪﻩ ﺍﻧﺪ 

ﺍﺗﺼﺎﻝ ﻧﺎﺩﺭﺳﺖ ﺳﻴﻢ   ﻫﺎﻱ ﻣﻮﺗﻮﺭ ﻓﻦ

ﺗﻌﻮﻳﺾ   ﻣﻮﺗﻮﺭﻓﻦ

ﺑﺮﺭﺳﻲ ﺑﺎ ﺭﻭﺵ ﻫﺎﻱ ﺗﺴﺘﻲ 

ﻣﺪﺍﺭﺍﺕ ﺩﺍﺧﻠﻲ ﻣﻮﺗﻮﺭ   ﻣﻌﻴﻮﺏ ﺷﺪﻩ ﺍﻧﺪ

 ﻣﻮﺗﻮﺭ ﺍﻳﺮﺍﺩ ﺩﺍﺭﺩ

13

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

ﺗﻌﻮﻳﺾ ﺑﺮﺩ ﺩﺍﺧﻠﻲ 

ﺑﺮﺭﺳﻲ ﺩﻳﺪﺍﺭﻱ ﻳﺎ ﺭﻭﺵ ﻫﺎﻱ ﺗﺴﺘﻲ 

  ﺑﺮﺩ ﻭﺍﺣﺪ ﺩﺍﺧﻠﻲ ﺍﻳﺮﺍﺩ ﺩﺍﺭﺩ

 ﺍﻳﺮﺍﺩ ﺑﺮﺩ     )( PCB ﺩﺍﺧﻠﻲ 

 

 BLDCﻧﺤﻮﻩ ﺗﺴﺖ ﻣﻮﺗﻮﺭ ﻓﻦ ﺭﻭﺵ ﺍﻭﻝ  ﻣﻮﺗﻮﺭ ﻓﻦ ﻗﺮﺍﺭ ﺩﺍﺩﻩ ﻭ ﭘﺮﺍپ ﻗﺮﻣﺰ ﺭﺍ 4ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﺑﺎﺯﺭ ﻗﺮﺍﺭ ﻣﻲ ﺩﻫﻴﻢ ﭘﺮﺍپ ﻣﺸﻜﻲ ﺭﺍ ﺭﻭﻱ ﭘﺎﻳﻪ ﺷﻤﺎﺭﻩ  ﻗﺮﺍﺭ ﻣﻲ ﺩﻫﻴﻢ ﺭﻭﻱ ﻫﻴﭽﻜﺪﺍﻡ ﺍﺯ ﭘﺎﻳﻪ ﻫﺎ ﺯﻣﺎﻧﻲ ﻛﻪ ﺑﺎ ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺗﺴﺖ ﻣﻲ 7 ﻭ 6 ﻭ 5 ﻭ 1ﺭﻭﻱ ﭘﺎﻳﻪ ﻫﺎﻱ ﺷﻤﺎﺭﻩ ﻛﻨﻴﻢ ﻧﺒﺎﻳﺪ ﺍﺗﺼﺎﻝ ﺑﺮﻗﺮﺍﺭ ﺑﺎﺷﺪ ﻳﺎ ﺑﻮﻕ ﺑﺰﻧﺪ ﺩﺭ ﺻﻮﺭﺕ ﺯﺩﻥ ﺑﻮﻕ ﻳﺎ ﺑﺎﺯﺭ، ﻣﻮﺗﻮﺭ ﻓﻦ ﺍﻳﺮﺍﺩ ﺩﺍﺭﺩ . ﺭﻭﺵ ﺩﻭﻡ  ﻛﻪ ﻣﺸﺘﺮﻙ ﻣﻲ ﺑﺎﺷﺪ ﻗﺮﺍﺭ ﻣﻲ 4 ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﺗﺴﺖ ﺍﻫﻢ ﻗﺮﺍ ﺭ ﻣﻲ ﺩﻫﻴﻢ -ﭘﺮﺍپ ﻣﺸﻜﻲ ﺭﺍ ﺭﻭﻱ ﭘﺎﻳﻪ ﺷﻤﺎﺭﻩ ﺩﻫﻴﻢ .ﻣﻘﺎﻭﻣﺖ ﻫﺎﻱ ﺳﺎﻟﻢ ﺩﺭ ﺭﻭﻱ ﻛﺎﻧﻜﺘﻮﺭ ﺑﻪ ﺻﻮﺭﺕ ﺯﻳﺮ ﻣﻲ ﺑﺎﺷﺪ : ∞   1 → 4 40    5→ 4 - 100K Ω ∞   6→ 4 4 →7  240 ﺗﺎ 260 kΩ

 

ﺭﻭﺵ ﺗﺴﺖ ﺑﺮﺩ ﺩﺭ ﺯﻣﺎﻧﻲ ﻛﻪ ﺩﺳﺘﮕﺎﻩ ﺍﺭﻭﺭ ﻣﻮﺗﻮﺭ ﻓﻦ ﻣﻲ ﺩﻫﺪ  ﻗﺮﺍﺭ ﺩﺍﺩﻩ ﻭ ﺑﻌﺪ ﺍﺯ 4 ﻗﺮﺍﺭ ﺩﺍﺩ ﻭ ﺳﭙﺲ ﭘﺮﺍپ ﻣﺸﻜﻲ ﺭﺍ ﺭﻭﻱ ﭘﺎﻳﻪ ﺷﻤﺎﺭﻩ DCﺍﻭﻝ ﺑﺎﻳﺪ ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ  ﺭﻭﻱ ﻭﻟﺘﺎژ ﺁﻥ ﺑﻪ ﺭﻭﺵ ﺯﻳﺮ ﻋﻤﻞ ﻣﻲ ﻛﻨﻴﻢ : VD 380-250    1→4 VDC 15   5→4 DC 6/2    6→4 DC  5-0   7→4

 

 

 

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 14

 

ﺭﻓﻊ ﺍﻳﺮﺍﺩﺍﺕ  /ﻛﺪ ﻫﺎﻱ ﺧﻄﺎﻱ ﻭﺍﺣﺪ ﺑﻴﺮﻭﻧﻲ   CH21ﻛﺪ ﺧﻄﺎﻱ

  ﻛﺪ ﺧﻄﺎ ﻋﻨﻮﺍﻥ  ﻋﻠﺖ ﺧﻄﺎ  ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ 

CH21

 DCﻭﻟﺘﺎژ ﺑﺎﻻ 

 ﺟﺮﻳﺎﻥ ﺑﺎﻻﻱ • ﻟﺤﻈﻪ ﺍﻱ     ﺟﺮﻳﺎﻥ ﻧﺎﻣﻲ ﺑﺎﻻ • ﺍﻳﺮﺍﺩ ﻗﺴﻤﺖ • IPM

 ﺟﺮﻳﺎﻥ ﻟﺤﻈﻪ ﺍﻱ ﺑﺎﻻ ﺩﺭ ﻳﻜﻲ ﺍﺯ ﻓﺎﺯﻫﺎ   • U,V,W  -ﻗﻔﻞ ﺷﺪﻥ ﻛﻤﭙﺮﺳﻮﺭ   U,V,W -ﺍﺗﺼﺎﻝ ﻧﺎﺩﺭﺳﺖ  Over Load ﺑﺮﻭﺯ ﺷﺮﺍﻳﻂ  • -ﺷﺎﺭژ ﮔﺎﺯ ﺯﻳﺎﺩ  - ﻃﻮﻝ ﻟﻮﻟﻪ ﺯﻳﺎﺩ - ﻧﺎﻣﻨﺎﺳﺐ ﺑﻮﺩﻥ ﻣﺤﻞ ﻗﺮﺍﺭ ﮔﻴﺮﻱ ﻳﻮﻧﻴﺖ ﺑﻴﺮﻭﻧﻲ )ﻋﺪﻡ ﺍﮔﺰﺍﺳﺖ ﻣﻨﺎﺳﺐ (     ﺍﻳﺮﺍﺩ ﻋﺎﻳﻖ ﺑﻨﺪﻱ ﻛﻤﭙﺮﺳﻮﺭ •

 

 

 

 

 

 

ﺑﺮﺭﺳﻲ ﺍﺗﺼﺎﻟﻲ ﻛﺎﻧﻜﺘﻮﺭ ﺳﻴﮕﻨﺎﻝ ﻭﺭﻭﺩﻱ  :IPM 1. . ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﺍﻫﻢ ﻣﺘﺮ ﻗﺮﺍﺭ ﺩﻫﻴﺪ  ﺭﺍ ﺩﺭ ﺣﺎﻟﺖ ﺧﺎﻣﻮﺵ ﺩﺳﺘﮕﺎﻩ (SMPS) IPM . ﻭﺿﻌﻴﺖ ﺍﺗﺼﺎﻟﻲ ﺑﻴﻦ ﭘﻴﻦ ﻫﺎﻱ ﻭﺭﻭﺩﻱ 2 ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ.

 

 

 

 

ﺑﺮﺍﻱ ﭼﻚ ﻛﺮﺩﻥ ﺑﺮﺩ ﻳﺎ ﻗﺴﻤﺖ ﻫﺎﻱ ﺍﻟﻜﺘﺮﻳﻜﻲ ﺩﻳﮕﺮ , ﺑﻌﺪ ﺍﺯ ﺧﺎﻣﻮﺵ ﻛﺮﺩﻥ ﺩﺭ ﺯﻣﺎﻥ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻫﺎ ﻣﻮﺍﻇﺐ ﺍﺗﺼﺎﻝ 3ﺩﺳﺘﮕﺎﻩ  ﺩﻗﻴﻘﻪ ﺻﺒﺮ ﻛﻨﻴﺪ. ﻛﻮﺗﺎﻩ ﺑﺎ ﻗﺴﻤﺖ . ﻫﺎﻱ ﺩﻳﮕﺮ ﺑﺎﺷﻴﺪ 

 

 !

 

15

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ﭼﮕﻮﻧﮕﻲ ﺑﺮﺭﺳﻲ ﻣﻘﺎﻭﻣﺖ ﻓﺎﺯﻫﺎﻱ ﻛﻤﭙﺮﺳﻮﺭ 

    ﻣﻘﺎﻭﻣﺖ ﻋﺎﻳﻘﻲ ﺑﻴﻦ ﻛﻤﭙﺮﺳﻮﺭ ﻭ ﻟﻮﻟﻪ ﻛﺸﻲ

 

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 16

 

  W ﻭU,V    ﻣﻘﺎﻭﻣﺖ ﺑﻴﻦ

 

 

 

 

 

. 1 ﻣﻘﺪﺍﺭ ﻣﻘﺎﻭﻣﺖ ﺑﻴﻦ ﻫﺮ ﺗﺮﻣﻴﻨﺎﻝ ﺑﺎ ﻟﻮﻟﻪ ﺑﺎﻳﺪ ﺑﻴﺸﺘﺮ ﺍﺯ ۞ ﻣﮕﺎ ﺍﻫﻢ ﺑﺎﺷﺪ . 1 ﺗﺎ 0/5 ﻣﻘﺎﻭﻣﺖ ﻫﺮ ﺳﻴﻢ ﭘﻴﭻ ﺑﺎ ﺳﻴﻢ ﭘﻴﭻ ﺩﻳﮕﺮ ﺑﺎﻳﺪ ﺑﻴﻦ ۞ ﺍﻫﻢ ﺑﺎﺷﺪ   ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﻢ IPM < ﭼﮕﻮﻧﻪ ﻣﺴﻴﺮ 21 >ﺧﻄﺎﻱ ﻛﺎﻧﻜﺘﻮﺭﻫﺎﻱ ﺑﺮﺩ ﺭﺍ ﺟﺪﺍ ﻛﻨﻴﺪ 1 - ﺭﻧﺞ ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﺳﻨﺠﺶ ﻭﻟﺘﺎژ ﺩﻳﻮﺩ ﻗﺮﺍﺭ ﺩﻫﻴﺪ 2 -  ﻭﻟﺘﺎژﻫﺎﻱ 3  ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻛﻨﻴﺪ1 ﻫﻤﺎﻧﻨﺪ ﺷﻜﻞ P~U/P~V/P~W

 

 ﻣﻘﺎﻭﻣﺖ ﺑﻴﻦ ﺳﻴﻢ ﭘﻴﭻ ﻫﺎ

 

 ﺩﺭﺟﻪ ﺳﺎﻧﺘﻴﮕﺮﺍﺩ20 ﻣﻘﺎﻭﻣﺖ ﺩﺭ

 ﻣﻘﺎﻭﻣﺖ ﺍﺗﺼﺎﻝ ﺑﺪﻧﻪ ﺳﻴﻢ ﭘﻴﭻ ﻫﺎ

17

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

ﻭﻟﺘﺎژﻫﺎﻱ 4  ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻛﻨﻴﺪ 2 ﻫﻤﺎﻧﻨﺪ ﺷﻜﻞ U~Nu/V~Nu/W~Nu ﺍﮔﺮ ﻣﻘﺎﺩﻳﺮ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ ﺑﻪ ﻃﻮﺭ ﻣﺸﺨﺺ ﺑﺎ ﻣﻘﺎﺩﻳﺮ ﻭﺍﻗﻌﻲ ﻣﺘﻔﺎﻭﺕ ﺑﺎﺷﻨﺪ 5 ﺍﻳﺮﺍﺩ ﺩﺍﺭﺩ ﻭ ﺑﺮﺩ ﺭﺍ IPM ﺗﻌﻮﻳﺾ ﻛﻨﻴﺪ 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 LED 1ﻣﺪﻝ ﻫﺎﻱ

 LED 2ﻣﺪﻝ ﻫﺎﻱ

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 18

 

 CH22ﻛﺪ ﺧﻄﺎﻱ

  ﻛﺪ ﺧﻄﺎ ﻋﻨﻮﺍﻥ  ﻋﻠﺖ ﺧﻄﺎ ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ 

22

CT2  ﺟﺮﻳﺎﻥ ﻭﺭﻭﺩﻱ ﺑﻴﺸﺘﺮ ﺍﺯ ﻣﻘﺪﺍﺭ   ﺗﻌﻴﻴﻦ ﺷﺪﻩ ﺍﺳﺖ

 ﻭﻟﺘﺎژ • ﺧﻄﺎﻱ ﻭﻟﺘﺎژ ﻭﺭﻭﺩﻱ ) ﭘﺎﻳﻴﻦ(  Over Load ﺷﺮﺍﻳﻂ •  ﺁﺳﻴﺐ ﺩﻳﺪﻥ ﺑﺮﺩ• 

  • ﻭﻟﺘﺎژ ﻭﺭﻭﺩﻱ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ •  ﺷﺮﺍﻳﻂ ﻓﻦ ﺑﻴﺮﻭﻧﻲ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ  •  ﻗﺴﻤﺖ ﻫﺎﻱ ﺳﻨﺴﻮﺭ ﺑﺮﺩ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ 

 

 

 

 

 

 

 

 

 

 

 

 

 

ﺑﺮﺍﻱ ﭼﻚ ﻛﺮﺩﻥ ﺑﺮﺩ ﻳﺎ ﻗﺴﻤﺖ ﻫﺎﻱ ﺍﻟﻜﺘﺮﻳﻜﻲ ﺩﻳﮕﺮ،ﺑﻌﺪ ﺍﺯ ﺧﺎﻣﻮﺵ ﻛﺮﺩﻥ ﺩﺭ ﺯﻣﺎﻥ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻫﺎ ﻣﻮﺍﻇﺐ ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﺑﺎ 3ﺩﺳﺘﮕﺎﻩ  ﺩﻗﻴﻘﻪ ﺻﺒﺮ ﻛﻨﻴﺪ . ﻗﺴﻤﺖ ﻫﺎﻱ ﺩﻳﮕﺮ ﺑﺎﺷﻴﺪ.

 !

 

19

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ

 

 

ﺩﺭ ﺗﻤﺎﻣﻲ ﺍﺭﻭﺭﻫﺎ:

ﺯﻣﺎﻧﻲ ﻛﻪ ﻫﻤﻪ ﻣﺮﺍﺣﻞ ﺑﺮﺭﺳﻲ ﺍﻧﺠﺎﻡ ﺷﺪ ﻭ ﺑﻪ ﺍﻳﻦ ﻧﺘﻴﺠﻪ ﺭﺳﻴﺪﻳﺪ ﻛﻪ ﺑﺮﺩ ﺭﺍ ﺗﻌﻮﻳﺾ ﻛﻨﻴﺪ , ﻗﺒﻞ ﺍﺯ ﺗﻌﻮﻳﺾ ﺑﺮﺩ ﺍﻗﺪﺍﻣﺎﺕ ﺯﻳﺮ ﺭﺍ ﺣﺘﻤﺎ ﺍﻧﺠﺎﻡ ﺩﻫﻴﺪ : 1 (ﺑﺮﻕ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﻗﻄﻊ ﻛﻨﻴﺪ 2 (ﺗﻤﺎﻣﻲ ﻛﺎﻧﻜﺘﻮﺭﻫﺎﻱ ﺑﺮﺩ ﺑﻴﺮﻭﻧﻲ ﻭ ﺑﺮﺩ ﺩﺍﺧﻠﻲ ﺭﺍ ﺍﺯ ﺭﻭﻱ ﺑﺮﺩ ﺟﺪﺍ ﻛﻨﻴﺪ 3 (ﭼﻨﺪ ﺩﻗﻴﻘﻪ ﺻﺒﺮ ﻛﻨﻴﺪ 4 (ﺳﭙﺲ ﺗﻤﺎﻣﻲ ﻛﺎﻧﻜﺘﻮﺭ ﻫﺎ ﺭﺍ ﺩﻭﺑﺎﺭﻩ ﻭﺻﻞ ﻛﻨﻴﺪ 5 (. ﺑﺮﻕ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﺩﻭﺑﺎﺭﻩ ﻭﺻﻞ ﻛﻨﻴﺪ ﻭ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﺭﻭﺷﻦ ﻛﻨﻴﺪ ﺩﺭ ﺻﻮﺭﺕ ﺑﺮﻭﺯ ﺩﻭﺑﺎﺭﻩ ﺍﺭﻭﺭ ﻧﺴﺒﺖ ﺑﻪ ﺗﻌﻮﻳﺾ ﺑﺮﺩ ﺍﻗﺪﺍﻡ ﻧﻤﺎﺋﻴﺪ .

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 20

 

  < ﭼﮕﻮﻧﻪ ﻣﻴﺰﺍﻥ ﻭﻟﺘﺎژ ﻭﺭﻭﺩﻱ ﺳﻨﺴﻮﺭ ﺟﺮﻳﺎﻥ ﺭﺍ  ﺍﻧﺪﺍﺯﻩ ﺑﮕﻴﺮﻳﺪ CH 22 > ﺍﺭﻭﺭ

ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻭﻟﺘﺎژ ﻭﺭﻭﺩﻱ ﺳﻨﺴﻮﺭ ﺟﺮﻳﺎﻥ ﺑﺮﺩ   ﻗﺮﺍﺭ ﺩﻫﻴﺪDC .ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮ 1  ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻛﻨﻴﺪstand by .ﻣﻘﺎﺩﻳﺮ ﺯﻳﺮ ﺭﺍ ﺩﺭ ﺣﺎﻟﺖ ﺍﺗﺼﺎﻝ ﺑﺮﻕ ﺗﻐﺬﻳﻪ ﺩﺭ ﺣﺎﻟﺖ 2         .ﺍﮔﺮ ﻣﻘﺎﺩﻳﺮ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ ﺑﻴﺮﻭﻥ ﺍﺯ ﻣﺤﺪﻭﺩﻩ ﻣﺠﺎﺯ ﺑﻮﺩ ﺍﺣﺘﻤﺎﻝ ﺳﻮﺧﺘﮕﻲ ﻗﻄﻌﻪ 3 ﻣﻲ ﺑﺎﺷﺪ.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  ﺩﺍﺭLED1 ﻣﺪﻝ

 ﺟﺮﻳﺎﻥ ﻭﺭﻭﺩﻱ

ﺍﮔﺮ ﻣﻘﺪﺍﺭ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ ﺑﻴﺮﻭﻥ  ﻭﻟﺖ ﺑﺎﺷﺪ 2/7 ﺍﻟﻲ 2/3ﺍﺯ ﻣﺤﺪﻭﺩﻩ   ﻗﻄﻌﻪ ﺍﻳﺮﺍﺩ ﺩﺍﺭﺩ

 

21

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  ﻛﺪ ﺧﻄﺎ ﻋﻨﻮﺍﻥ  ﻋﻠﺖ ﺧﻄﺎ  ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ 

23

 DCﻭﻟﺘﺎژ ﭘﺎﺋﻴﻦ ﺧﻂ  v rms  140ﻛﻤﺘﺮ ﺍﺯ

  • ﺧﻄﺎﻱ ﻭﻟﺘﺎژ ﻭﺭﻭﺩﻱ )ﻭﻟﺘﺎژ ﭘﺎﺋﻴﻦ (   ﺳﻮﺧﺘﮕﻲ ﻗﻄﻌﻪ • ﺩﺭ ﺑﺮﺩ 
  • ﺑﺮﺭﺳﻲ ﻭﻟﺘﺎژ ﻭﺭﻭﺩﻱ ﺑﺮﺭﺳﻲ ﻗﺴﻤﺖ • ﻫﺎﻱ ﺳﻨﺴﻮﺭ ﻭﻟﺘﺎژ  DCﺧﻂ

 

 

               

 

 ﺩﺍﺭLED2ﻣﺪﻝ

   ﻭﻟﺖ ﺑﺎﺷﺪ ﻗﻄﻌﻪ ﺍﻳﺮﺍﺩ ﺩﺍﺭﺩ2/7  ﺍﻟﻲ2/3 ﺍﮔﺮ ﻣﻘﺪﺍﺭ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ ﺑﻴﺮﻭﻥ ﺍﺯ ﻣﺤﺪﻭﺩﻩ

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 22

 

 

 

 

ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ ! 

 

 

 

 

 

  ﺑﻌﺪ ﺍﺯ ﺧﺎﻣﻮﺵ ﻛﺮﺩﻥ ، ﺑﺮﺍﻱ ﭼﻚ ﻛﺮﺩﻥ ﺑﺮﺩ ﻳﺎ  ﻗﺴﻤﺖ ﻫﺎﻱ ﺍﻟﻜﺘﺮﻳﻜﻲ ﺩﻳﮕﺮ ﺩﺭ ﺯﻣﺎﻥ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻫﺎ ﻣﻮﺍﻇﺐ ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﺑﺎ 3ﺩﺳﺘﮕﺎﻩ ﺩﻗﻴﻘﻪ ﺻﺒﺮ ﻛﻨﻴﺪ. ﻗﺴﻤﺖ . ﻫﺎﻱ ﺩﻳﮕﺮ ﺑﺎﺷﻴﺪ 

 

 

 

 !

DC  ﻟﻳﻧﮏ

 

23

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

ﺩﺭ ﺗﻤﺎﻣﻲ ﺍﺭﻭﺭﻫﺎ:

ﺯﻣﺎﻧﻲ ﻛﻪ ﻫﻤﻪ ﻣﺮﺍﺣﻞ ﺑﺮﺭﺳﻲ ﺍﻧﺠﺎﻡ ﺷﺪ ﻭ ﺑﻪ ﺍﻳﻦ ﻧﺘﻴﺠﻪ ﺭﺳﻴﺪﻳﺪ ﻛﻪ ﺑﺮﺩ ﺭﺍ ﺗﻌﻮﻳﺾ ﻛﻨﻴﺪ , ﻗﺒﻞ ﺍﺯ ﺗﻌﻮﻳﺾ ﺑﺮﺩ ﺍﻗﺪﺍﻣﺎﺕ ﺯﻳﺮ ﺭﺍ ﺣﺘﻤﺎ ﺍﻧﺠﺎﻡ ﺩﻫﻴﺪ :  1 (ﺑﺮﻕ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﻗﻄﻊ ﻛﻨﻴﺪ 2 (ﺗﻤﺎﻣﻲ ﻛﺎﻧﻜﺘﻮﺭﻫﺎﻱ ﺑﺮﺩ ﺑﻴﺮﻭﻧﻲ ﻭ ﺑﺮﺩ ﺩﺍﺧﻠﻲ ﺭﺍ ﺍﺯ ﺭﻭﻱ ﺑﺮﺩ ﺟﺪﺍ ﻛﻨﻴﺪ

 3 (ﭼﻨﺪ ﺩﻗﻴﻘﻪ ﺻﺒﺮ ﻛﻨﻴﺪ 4 (ﺳﭙﺲ ﺗﻤﺎﻣﻲ ﻛﺎﻧﻜﺘﻮﺭ ﻫﺎ ﺭﺍ ﺩﻭﺑﺎﺭﻩ ﻭﺻﻞ ﻛﻨﻴﺪ 5 (. ﺑﺮﻕ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﺩﻭﺑﺎﺭﻩ ﻭﺻﻞ ﻛﻨﻴﺪ ﻭ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﺭﻭﺷﻦ ﻛﻨﻴﺪ ﺩﺭ ﺻﻮﺭﺕ ﺑﺮﻭﺯ ﺩﻭﺑﺎﺭﻩ ﺍﺭﻭﺭ ﻧﺴﺒﺖ ﺑﻪ ﺗﻌﻮﻳﺾ ﺑﺮﺩ ﺍﻗﺪﺍﻡ ﻧﻤﺎﺋﻴﺪ .

 

 < ﭼﮕﻮﻧﻪ ﻣﻴﺰﺍﻥ ﻭﻟﺘﺎژ ﻭﺭﻭﺩﻱ ﺳﻨﺴﻮﺭ ﺟﺮﻳﺎﻥ ﺭﺍ  ﺍﻧﺪﺍﺯﻩ ﺑﮕﻴﺮﻳﺪ  CH 22 > ﺍﺭﻭﺭ

 

ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻭﻟﺘﺎژ ﻭﺭﻭﺩﻱ ﺳﻨﺴﻮﺭ ﺟﺮﻳﺎﻥ ﺑﺮﺩ   ﻗﺮﺍﺭ ﺩﻫﻴﺪDC .ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮ 1  ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻛﻨﻴﺪstand by .ﻣﻘﺎﺩﻳﺮ ﺯﻳﺮ ﺭﺍ ﺩﺭ ﺣﺎﻟﺖ ﺍﺗﺼﺎﻝ ﺑﺮﻕ ﺗﻐﺬﻳﻪ ﺩﺭ ﺣﺎﻟﺖ 2         .ﺍﮔﺮ ﻣﻘﺎﺩﻳﺮ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ ﺑﻴﺮﻭﻥ ﺍﺯ ﻣﺤﺪﻭﺩﻩ ﻣﺠﺎﺯ ﺑﻮﺩ ﺍﺣﺘﻤﺎﻝ ﺳﻮﺧﺘﮕﻲ ﻗﻄﻌﻪ 3 ﻣﻲ ﺑﺎﺷﺪ.

 

 

 

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ﺍﮔﺮ ﻣﻴﺰﺍﻥ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ ﺑﻴﺮﻭﻥ ﺍﺯ  ﺑﺎﺷﺪ DC  ﻭﻟﺖ2/8 ﺍﻟﻲ 2/4ﻣﺤﺪﻭﺩﻩ ﻗﻄﻌﻪ ﻣﻌﻴﻮﺏ ﺍﺳﺖ.

 

 

 

 2/4ﺍﮔﺮ ﻣﻴﺰﺍﻥ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ ﺑﻴﺮﻭﻥ ﺍﺯ ﻣﺤﺪﻭﺩﻩ . DC  ﻭﻟﺖ2/8ﺍﻟﻲ  ﺑﺎﺷﺪ ﻗﻄﻌﻪ ﻣﻌﻴﻮﺏ ﺍﺳﺖ 

 

25

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

ﺍﺭﻭﺭ   CH 26

  ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ ﻋﻠﺖ ﺧﻄﺎ  ﻋﻨﻮﺍﻥ  ﻛﺪ ﺧﻄﺎ 

  • ﺑﺮﺭﺳﻲ ﻗﻔﻞ ﺷﺪﮔﻲ ﻛﻤﭙﺮﺳﻮﺭ ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﺳﻴﻤﻬﺎﻱ • ﺑﺎﺯ/ ﻛﻤﭙﺮﺳﻮﺭ   ﺍﺗﺼﺎﻝ • ﺑﺮﺭﺳﻲ ﻋﺎﻳﻖ ﻛﻤﭙﺮﺳﻮﺭ ) ﺑﺪﻧﻪ (  •  ﻗﻔﻞ ﺷﺪﮔﻲ ﺑﺮﺭﺳﻲ ﻓﻦ ﺑﻴﺮﻭﻧﻲ  : –... ﻣﺴﻴﺮ ﺑﺎﺩ-ﻭ  •  ﺑﺮﺭﺳﻲ  ﺑﻪ ﺍﺭﻭﺭ IPM )21 ﻣﺮﺍﺟﻌﻪ ﺷﻮﺩ (   ﺑﺮﺭﺳﻲ ﻗﺴﻤﺖ ﺣﺴﮕﺮ ﺟﺮﻳﺎﻥ • ﻓﺎﺯﻱ ﺑﺮﺩ 
  • ﻗﻔﻞ ﺷﺪﮔﻲ ﻛﻤﭙﺮﺳﻮﺭ ﺣﺎﻟﺖ ﺍﻭﺭ ﻟﻮﺩ • ﻗﻔﻞ – )ﺗﻮﻗﻒ ﻓﻦ ﺑﻴﺮﻭﻧﻲ ﺷﺪﮔﻲ ﻓﻦ ﺑﻴﺮﻭﻧﻲ ﻭ...(  •  ﺳﻮﺧﺘﮕﻲ ﻗﻄﻌﺎﺕ ﺭﻭﻱ ﺑﺮﺩ )IPM(   •  ﺳﻮﺧﺘﮕﻲ ﻗﺴﻤﺖ ﻫﺎﻱ ﻣﺴﻴﺮ ﺣﺴﮕﺮ ﺟﺮﻳﺎﻥ ﻓﺎﺯ ﺩﺭ ﺑﺮﺩ 

ﺍﺭﻭﺭ ﻣﻮﻗﻌﻴﺖ CH26   ﻛﻤﭙﺮﺳﻮﺭDC

 

 

 

 

 

 

 

 

 

 

  ﺑﻌﺪ ﺍﺯ ﺧﺎﻣﻮﺵ ﻛﺮﺩﻥ ﺩﺳﺘﮕﺎﻩ ، ﺑﺮﺍﻱ ﭼﻚ ﻛﺮﺩﻥ ﺑﺮﺩ ﻳﺎ  ﻗﺴﻤﺖ ﻫﺎﻱ ﺍﻟﻜﺘﺮﻳﻜﻲ ﺩﻳﮕﺮ ﺩﺭ ﺯﻣﺎﻥ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻫﺎ ﻣﻮﺍﻇﺐ ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﺑﺎ ﻗﺴﻤﺖ 3 ﺩﻗﻴﻘﻪ ﺻﺒﺮ ﻛﻨﻴﺪ. ﻫﺎﻱ ﺩﻳﮕﺮ ﺑﺎﺷﻴﺪ. 

 

 

 

 !

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 26

 

ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ!  

 

   < ﭼﮕﻮﻧﮕﻲ ﺑﺮﺭﺳﻲ ﺟﺮﻳﺎﻥ ﻓﺎﺯﻱ CH 26 >ﺍﺭﻭﺭ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻭﻟﺘﺎژ ﻗﺴﻤﺖ ﺣﺴﮕﺮ ﺟﺮﻳﺎﻥ ﻓﺎﺯ 

ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻭﻟﺘﺎژ ﻭﺭﻭﺩﻱ ﺳﻨﺴﻮﺭ ﺟﺮﻳﺎﻥ ﺑﺮﺩ   ﻗﺮﺍﺭ ﺩﻫﻴﺪDC .ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮ 1  ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻛﻨﻴﺪstand by .ﻣﻘﺎﺩﻳﺮ ﺯﻳﺮ ﺭﺍ ﺩﺭ ﺣﺎﻟﺖ ﺍﺗﺼﺎﻝ ﺑﺮﻕ ﺗﻐﺬﻳﻪ ﺩﺭ ﺣﺎﻟﺖ 2 3 .. ﺍﮔﺮ ﻣﻘﺎﺩﻳﺮ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ ﺑﻴﺮﻭﻥ ﺍﺯ ﻣﺤﺪﻭﺩﻩ ﻣﺠﺎﺯ ﺑﻮﺩ ﺍﺣﺘﻤﺎﻝ ﺳﻮﺧﺘﮕﻲ ﻗﻄﻌﻪ ﻣﻴﺒﺎﺷﺪ

27

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC  2/7 ﺍﻟﻲ 2/3ﺍﮔﺮ ﻣﻴﺰﺍﻥ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ ﺑﻴﺮﻭﻥ ﺍﺯ ﻣﻘﺪﺍﺭ ﺑﺎﺷﺪ ﻗﻄﻌﻪ ﻣﻌﻴﻮﺏ ﺍﺳﺖ. 

 

 

  ﺩﺍﺭ LED 1ﻣﺪﻝ

 

ﺍﮔﺮ ﻣﻴﺰﺍﻥ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ ﺑﻴﺮﻭﻥ ﺍﺯ ﺑﺎﺷﺪ ﻗﻄﻌﻪ ﻣﻌﻴﻮﺏ DC  2/7 ﺍﻟﻲ 2/3ﻣﻘﺪﺍﺭ ﺍﺳﺖ. 

 

 

   ﺩﺍﺭLED 2ﻣﺪﻝ

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 28

 

ﻣﺪﺍﺭ ﺁﺷﻜﺎﺭ ﺳﺎﺯ ﺟﺮﻳﺎﻥ ﻓﺎﺯ ﻛﻤﭙﺮﺳﻮﺭ 

 

ﻫﺪﻑ

 

ﺗﺸﺨﻴﺺ ﺍﻳﺠﺎﺩ ﺟﺮﻳﺎﻥ ﺑﺎﻻﻱ ﻛﻤﭙﺮﺳﻮﺭ ﺑﺪﻟﻴﻞ ﺍﺭﻭﺭ ﺁﺷﻜﺎﺭﺳﺎﺯ ﺟﺮﻳﺎﻥ ﻓﺎﺯ 

 

ﻣﻮﺍﺭﺩ ﺑﺮﺭﺳﻲ

 

. ﺑﺮﺭﺳﻲ ﺍﺭﻭﺭ ﺟﺮﻳﺎﻥ 1 ﺁﺷﻜﺎﺭﺳﺎﺯ

 

ﺭﻭﺵ ﺑﺮﺭﺳﻲ 

 

 

 

 

 

 

 

 

 

 

 

 

 ﺑﺮﻕ ﺭﺍ ﻭﺻﻞ ﻛﻨﻴﺪ

ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ ﺭﺍ ﺧﺎﻣﻮﺵ  ﻛﻨﻴﺪ

 ﻭﻟﺘﺎژ ﺭﺍ ﺍﻧﺪﺍﺯﻩ ﺑﮕﻴﺮﻳﺪ

 ﺑﺮﺩ ﺭﺍ ﺗﻌﻮﻳﺾ ﻛﻨﻴﺪ ﺁﺷﻜﺎﺭ ﺳﺎﺯ ﺟﺮﻳﺎﻥ   ﻧﺮﻣﺎﻝ ﺍﺳﺖ

  ﻭﻟﺖ2/7 ﺍﻟﻲ 2/3ﺑﻴﻦ ﺧﻴﺮ ﺑﻠﻪ

 

29

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

ﺗﻮﺟﻪ !

ﻭﻗﺘﻲ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻣﻴﻜﻨﻴﺪ ﻭ ﺑﺮﻕ ﺑﻪ ﺩﺳﺘﮕﺎﻩ ﻭﺻﻞ ﺍﺳﺖ, ﺩﻗﺖ ﻛﻨﻴﺪ ﺭﻧﺞ ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺩﺭﺳﺖ ﺍﻧﺘﺨﺎﺏ ﺷﺪﻩ ﺑﺎﺷﺪ ﻭ ﻣﻮﺍﻇﺐ ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﺑﺎ ﺩﻳﮕﺮ ﻗﺴﻤﺖ ﻫﺎﻱ ﺑﺮﺩ ﺑﺎﺷﻴﺪ. 

ﺭﻧﺞ ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﻭﻟﺘﺎژ 1  ﮔﺬﺍﺷﺘﻪ ﻭ ﺟﺮﻳﺎﻥ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪDC ﻭﻟﺘﺎژ 2  ﺍﻧﺪﺍﺯﻩ ﺑﮕﻴﺮﻳﺪGND ﺭﺍﺑﺎ U ,V,W ﻣﻘﺪﺍﺭ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ 3  ﻭﻟﺖ ﻣﻲ ﺑﺎﺷﺪ2/5 ± 0/5 ﺩﺭ ﺻﻮﺭﺕ ﺩﺭﺳﺖ ﻧﺒﻮﺩﻥ ﻭﻟﺘﺎژ ﺑﺮﺩ ﺭﺍ ﺗﻌﻮﻳﺾ ﻛﻨﻴﺪ 4 - 

 

 

  ﻛﺪ ﺧﻄﺎ ﻋﻨﻮﺍﻥ  ﻋﻠﺖ ﺧﻄﺎ  ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ 

CH27

ﺍﺭﻭﺭ ﺟﺮﻳﺎﻥ ﺑﺎﻻﻱ ﺧﻄﺎﻱ PSC 

  • Over Load ﺷﺮﺍﻳﻂ ﺍﻳﺮﺍﺩ  ﺭﺍﻛﺘﻮﺭ  ﺳﻮﺧﺘﮕﻲ ﻗﻄﻌﺎﺕ ﺩﺍﺧﻠﻲ ﺑﺮﺩ  • )PSC ( 

 ﺍﻳﺮﺍﺩ ﺑﺮﺭﺳﻲ ﻣﻮﺗﻮﺭ ﻓﻦ ﺑﻴﺮﻭﻧﻲ / ﻓﻦ/ﺟﻬﺖ ﻭﺯﺵ ﺑﺎﺩ  ﺑﺮﺭﺳﻲ ﺷﺮﺍﻳﻂ ﺭﺍﻛﺘﻮﺭ : 10A/26.8mH ﺑﺮﺭﺳﻲ ﻗﻄﻌﺎﺕ ﺩﺍﺧﻠﻲ ﺑﺮﺩ ﺍﺻﻠﻲ 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 30

 

 

 

 

 

: PSCﺑﺮﺭﺳﻲ ﻛﺮﺩﻥ ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﻛﺎﻧﻜﺘﻮﺭ ﺳﻴﮕﻨﺎﻝ ﻭﺭﻭﺩﻱ ﻣﺪﻭﻻﺗﻮﺭ  ﺑﺮﺩ ﺍﺻﻠﻲ   . ﻗﺮﺍﺭ ﺩﻫﻴﺪDC .ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﺗﺴﺖ ﻭﻟﺘﺎژ 1 .ﺩﺭ ﺣﺎﻟﺖ ﺧﺎﻣﻮﺵ ﺩﺳﺘﮕﺎﻩ ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﭘﻴﻦ ﻫﺎﻱ ﺳﻴﮕﻨﺎﻝ ﻭﺭﻭﺩﻱ ﺍﺯ ﻗﺴﻤﺖ ﭘﺎﻳﺌﻦ ﺭﺍ ﺑﺮﺭﺳﻲ 2 ﻛﻨﻴﺪ.

  

 

ﺑﺮﺍﻱ ﭼﻚ ﻛﺮﺩﻥ ﺑﺮﺩ ﻳﺎ ﻗﺴﻤﺖ ﻫﺎﻱ ﺍﻟﻜﺘﺮﻳﻜﻲ ﺩﻳﮕﺮ , ﺑﻌﺪ ﺍﺯ ﺧﺎﻣﻮﺵ ﻛﺮﺩﻥ ﺩﺭ ﺯﻣﺎﻥ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻫﺎ ﻣﻮﺍﻇﺐ ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﺑﺎ 3ﺩﺳﺘﮕﺎﻩ  ﺩﻗﻴﻘﻪ ﺻﺒﺮ ﻛﻨﻴﺪ. ﻗﺴﻤﺖ ﻫﺎﻱ ﺩﻳﮕﺮ ﺑﺎﺷﻴﺪ. 

 

 

 

 !

 ﺗﻮﺟﻪ: . 5ﻭ4ﭘﻴﻦ ﻫﺎﻱ   ﺍﺯ ﺩﺍﺧﻞ ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﻫﺴﺘﻨﺪ

31

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

 

 

ﻣﺪﺍﺭ ﺁﺷﻜﺎﺭ ﺳﺎﺯ ﺟﺮﻳﺎﻥ ﻓﺎﺯ ﻛﻤﭙﺮﺳﻮﺭ 

 

 

 

 

 

ﻫﺪﻑ ﺗﺸﺨﻴﺺ ﺍﻳﺠﺎﺩ ﺟﺮﻳﺎﻥ ﺑﺎﻻﻱ ﻛﻤﭙﺮﺳﻮﺭ ﺑﺪﻟﻴﻞ ﺍﺭﻭﺭ ﺁﺷﻜﺎﺭﺳﺎﺯ ﺟﺮﻳﺎﻥ ﻓﺎﺯ 

 

ﻣﻮﺍﺭﺩ ﺑﺮﺭﺳﻲ 

 

. ﺑﺮﺭﺳﻲ ﺍﺭﻭﺭ ﺟﺮﻳﺎﻥ 1 ﺁﺷﻜﺎﺭﺳﺎﺯ 

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 32

 

ﺭﻭﺵ ﺑﺮﺭﺳﻲ 

 

 

 

 

 

 

 

 

 

 

 

ﺗﻮﺟﻪ !  ﺩﻗﺖ ﻛﻨﻴﺪ ﺭﻧﺞ ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺩﺭﺳﺖ ،ﻭﻗﺘﻲ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻣﻴﻜﻨﻴﺪ ﻭ ﺑﺮﻕ ﺑﻪ ﺩﺳﺘﮕﺎﻩ ﻭﺻﻞ ﺍﺳﺖ ﺍﻧﺘﺨﺎﺏ ﺷﺪﻩ ﺑﺎﺷﺪ ﻭ ﻣﻮﺍﻇﺐ ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﺑﺎ ﺩﻳﮕﺮ ﻗﺴﻤﺖ ﻫﺎﻱ ﺑﺮﺩ ﺑﺎﺷﻴﺪ. 

ﺭﻧﺞ ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﻭﻟﺘﺎژ 1   ﮔﺬﺍﺷﺘﻪ ﻭ ﺟﺮﻳﺎﻥ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪDC ﺟﺮﻳﺎﻥ ﺑﻴﻦ 2 . Micom _GND ﻭ Input _I  ﺭﺍﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ ﻣﻘﺪﺍﺭ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ 3  ﻭﻟﺖ ﻣﻲ ﺑﺎﺷﺪ2/5 ±0/5 ﺩﺭ ﺻﻮﺭﺕ ﺩﺭﺳﺖ ﻧﺒﻮﺩﻥ ﻭﻟﺘﺎژ ﺑﺮﺩ ﺭﺍ ﺗﻌﻮﻳﺾ ﻛﻨﻴﺪ 4 -

 ﺑﺮﻕ ﺭﺍ ﻭﺻﻞ ﻛﻨﻴﺪ

ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ ﺭﺍ ﺧﺎﻣﻮﺵ  ﻛﻨﻴﺪ

 ﻭﻟﺘﺎژ ﺭﺍ ﺍﻧﺪﺍﺯﻩ ﺑﮕﻴﺮﻳﺪ

 ﺑﺮﺩ ﺭﺍ ﺗﻌﻮﻳﺾ ﻛﻨﻴﺪ ﺁﺷﻜﺎﺭ ﺳﺎﺯ ﺟﺮﻳﺎﻥ   ﻧﺮﻣﺎﻝ ﺍﺳﺖ

 ﻭﻟﺖ2/7 ﺍﻟﻲ 2/3 ﺑﻴﻦ ﺧﻴﺮ ﺑﻠﻪ

 

33

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

 

 

( CH 29ﺍﺭﻭﺭ  )ﺍﺭﻭﺭ ﺟﺮﻳﺎﻥ ﺑﺎﻻﻱ ﻛﻤﭙﺮﺳﻮﺭ ﺍﻳﻨﻮﺭﺗﺮ 

  ﻛﺪ ﺧﻄﺎ ﻋﻨﻮﺍﻥ  ﻋﻠﺖ ﺧﻄﺎ  ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ 

ﺍﺭﻭﺭ ﺟﺮﻳﺎﻥ ﺑﺎﻻﻱ ﻓﺎﺯ CH29  ﻛﻤﭙﺮﺳﻮﺭ 

  • ﻗﻔﻞ ﺷﺪﮔﻲ ﻛﻤﭙﺮﺳﻮﺭ ﺣﺎﻟﺖ ﺍﻭﺭ ﻟﻮﺩ • ﻗﻔﻞ – )ﺗﻮﻗﻒ ﻓﻦ ﺑﻴﺮﻭﻧﻲ ﺷﺪﮔﻲ ﻓﻦ ﺑﻴﺮﻭﻧﻲ ﻭ...(  •  ﺳﻮﺧﺘﮕﻲ ﻗﺴﻤﺖ ﺣﺴﮕﺮ ﺟﺮﻳﺎﻥ ﻓﺎﺯ ﺩﺭ ﺑﺮﺩ 
  • ﺑﺮﺭﺳﻲ ﻗﻔﻞ ﺷﺪﮔﻲ ﻛﻤﭙﺮﺳﻮﺭ •  : ﺑﺮﺭﺳﻲ ﻓﻦ ﺑﻴﺮﻭﻧﻲ ﻣﺴﻴﺮ –ﻗﻔﻞ ﺷﺪﮔﻲ ﺑﺎﺩ-ﻭ...   ﺑﺮﺭﺳﻲ ﻗﺴﻤﺖ  • ﺣﺴﮕﺮ ﺟﺮﻳﺎﻥ  ﻓﺎﺯﻱ ﺑﺮﺩ 

 

 

 

 

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 34

 

ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ  !

 

 

 

 

 

35

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

ﺩﺭ ﺗﻤﺎﻣﻲ ﺍﺭﻭﺭﻫﺎ:  ﻗﺒﻞ ﺍﺯ ،ﺯﻣﺎﻧﻲ ﻛﻪ ﻫﻤﻪ ﻣﺮﺍﺣﻞ ﺑﺮﺭﺳﻲ ﺍﻧﺠﺎﻡ ﺷﺪ ﻭ ﺑﻪ ﺍﻳﻦ ﻧﺘﻴﺠﻪ ﺭﺳﻴﺪﻳﺪ ﻛﻪ ﺑﺮﺩ ﺭﺍ ﺗﻌﻮﻳﺾ ﻛﻨﻴﺪ ﺗﻌﻮﻳﺾ ﺑﺮﺩ ﺍﻗﺪﺍﻣﺎﺕ ﺯﻳﺮ ﺭﺍ ﺣﺘﻤﺎ ﺍﻧﺠﺎﻡ ﺩﻫﻴﺪ : 1 (ﺑﺮﻕ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﻗﻄﻊ ﻛﻨﻴﺪ 2 (ﺗﻤﺎﻣﻲ ﻛﺎﻧﻜﺘﻮﺭﻫﺎﻱ ﺑﺮﺩ ﺑﻴﺮﻭﻧﻲ ﻭ ﺑﺮﺩ ﺩﺍﺧﻠﻲ ﺭﺍ ﺍﺯ ﺭﻭﻱ ﺑﺮﺩ ﺟﺪﺍ ﻛﻨﻴﺪ 3 (ﭼﻨﺪ ﺩﻗﻴﻘﻪ ﺻﺒﺮ ﻛﻨﻴﺪ 4 (ﺳﭙﺲ ﺗﻤﺎﻣﻲ ﻛﺎﻧﻜﺘﻮﺭ ﻫﺎ ﺭﺍ ﺩﻭﺑﺎﺭﻩ ﻭﺻﻞ ﻛﻨﻴﺪ 5 (. ﺑﺮﻕ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﺩﻭﺑﺎﺭﻩ ﻭﺻﻞ ﻛﻨﻴﺪ ﻭ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﺭﻭﺷﻦ ﻛﻨﻴﺪ ﺩﺭ ﺻﻮﺭﺕ ﺑﺮﻭﺯ ﺩﻭﺑﺎﺭﻩ ﺍﺭﻭﺭ ﻧﺴﺒﺖ ﺑﻪ ﺗﻌﻮﻳﺾ ﺑﺮﺩ ﺍﻗﺪﺍﻡ ﻧﻤﺎﺋﻴﺪ.

 

   <ﭼﮕﻮﻧﮕﻲ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺟﺮﻳﺎﻥ ﻓﺎﺯﻱ CH 29 >ﺍﺭﻭﺭ

ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻭﻟﺘﺎژ ﻗﺴﻤﺖ ﺣﺴﮕﺮ ﺟﺮﻳﺎﻥ ﻓﺎﺯ

  .ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻭﻟﺘﺎژ 1 . ﻗﺮﺍﺭ ﺩﻫﻴﺪDC . ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻛﻨﻴﺪStandby .ﺩﺭ ﺣﺎﻟﺖ ﺍﺗﺼﺎﻝ ﺑﺮﻕ ﺗﻐﺬﻳﻪ ﻭ ﺩﺭ ﺣﺎﻟﺖ 2 . DC ﻭﻟﺖ 2/7 ﺍﻟﻲ 2/3 .ﻣﻘﺪﺍﺭ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ 3 ﻣﻲ ﺑﺎﺷﺪ 

 

 

 

 

 

 

 ﺩﺍﺭ LEDﻣﺪﻝ ﻳﻚ

 

 DC 2/7 ﺍﻟﻲ 2/3ﺍﮔﺮ ﻣﻴﺰﺍﻥ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ ﺑﻴﺮﻭﻥ ﺍﺯ ﻣﻘﺪﺍﺭ ﺑﺎﺷﺪ. ﻗﻄﻌﻪ ﻣﻌﻴﻮﺏ ﺍﺳﺖ

 

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 36

 

 

 

 

 

 

 

 

( CH 32    ﺍﺭﻭﺭ  )ﺍﺭﻭﺭ ﮔﺮﻣﺎﻱ ﺑﻴﺶ ﺍﺯ ﺣﺪ ﻟﻮﻟﻪ ﺩﻫﺶ 

  ﻛﺪ ﺧﻄﺎ ﻋﻨﻮﺍﻥ  ﻋﻠﺖ ﺧﻄﺎ  ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ 

CH32

ﺩﻣﺎﻱ ﺑﺎﻻﻱ ﻟﻮﻟﻪ   ﺩﻫﺶ ﻛﻤﭙﺮﺳﻮﺭ (105℃(221℉)↑)

   ﺣﺎﻟﺖ ﺍﻭﺭ ﻟﻮﺩ •  ﺗﻮﻗﻒ ﻓﻦ ﺑﻴﺮﻭﻧﻲ )– ﻗﻔﻞ ﺷﺪﮔﻲ ﻓﻦ ﺑﻴﺮﻭﻧﻲ ﻭ...(     ﻧﺸﺘﻲ ﻣﺒﺮﺩ • •  ﺧﺮﺍﺑﻲ ﺳﻨﺴﻮﺭ ﺩﻫﺶ ﻛﻤﭙﺮﺳﻮﺭ ﺍﻳﻨﻮﺭﺗﺮ   / LEV ﺍﻳﺮﺍﺩ ﻛﺎﻧﻜﺘﻮﺭ • ﺧﺮﺍﺑﻲ  LEV

  • : ﺑﺮﺭﺳﻲ ﻓﻦ ﺑﻴﺮﻭﻧﻲ - –ﻗﻔﻞ ﺷﺪﮔﻲ ﻣﺴﻴﺮ ﺑﺎﺩ ﻭ... ﻧﺸﺘﻲ ﻣﺒﺮﺩ ﺭﺍ ﺑﺮﺭﺳﻲ • ﻛﻨﻴﺪ   ﺳﻨﺴﻮﺭ ﺭﺍ ﺑﺮﺭﺳﻲ • ﻛﻨﻴﺪ )ﻣﺤﻞ ﻗﺮﺍﺭ ﮔﻴﺮﻱ ﻭ ﺍﻫﻢ ﺳﻨﺴﻮﺭ (   ﺭﺍ LEV ﻭﺿﻌﻴﺖ • ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ 

 

 

 

  ﺩﺍﺭLEDﻣﺪﻝ ﺩﻭ

 

 ﺍﻟﻲ 2/3ﺍﮔﺮ ﻣﻴﺰﺍﻥ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ ﺑﻴﺮﻭﻥ ﺍﺯ ﻣﻘﺪﺍﺭ   ﺑﺎﺷﺪ ﻗﻄﻌﻪ ﻣﻌﻴﻮﺏ ﺍﺳﺖ DC 2/7

 

 

 

  ﺑﻌﺪ ﺍﺯ ﺧﺎﻣﻮﺵ ، ﺑﺮﺍﻱ ﭼﻚ ﻛﺮﺩﻥ ﺑﺮﺩ ﻳﺎ ﻗﺴﻤﺖ ﻫﺎﻱ ﺍﻟﻜﺘﺮﻳﻜﻲ ﺩﻳﮕﺮ ﺩﺭ ﺯﻣﺎﻥ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻫﺎ ﻣﻮﺍﻇﺐ 3ﻛﺮﺩﻥ ﺩﺳﺘﮕﺎﻩ  ﺩﻗﻴﻘﻪ ﺻﺒﺮ ﻛﻨﻴﺪ. ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﺑﺎ ﻗﺴﻤﺖ ﻫﺎﻱ ﺩﻳﮕﺮ ﺑﺎﺷﻴﺪ. 

 

 

 

  !

37

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ ! 

 

 

 

 

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 38

 

 < ﭼﮕﻮﻧﮕﻲ ﺑﺮﺭﺳﻲ ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ ﺩﻫﺶ CH32 >ﺍﺭﻭﺭ

ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻣﻘﺎﻭﻣﺖ ﻟﻮﻟﻪ ﺩﻫﺶ ﻛﻤﭙﺮﺳﻮﺭ 

 

 

 

1.5kw Controller(UA3)

 

 2kw Controller(UL,UL2)

 

 

   4kw Controller(UE,UE1)

 

 

 ﺳﻨﺴﻮﺭ

 ﺳﻨﺴﻮﺭ

 ﺳﻨﺴﻮﺭ

39

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

 

(25 200kΩ±10% ﻣﻴﺰﺍﻥ ﻣﻘﺎﻭﻣﺖ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ ℃)    ﻣﺤﻞ ﻗﺮﺍﺭﮔﻴﺮﻱ ﺳﻨﺴﻮﺭ ﺩﻫﺶ ﻛﻤﭙﺮﺳﻮﺭ

 

 

ﺍﺭﻭﺭ ﺳﻨﺴﻮﺭ CH 40ﺍﺭﻭﺭ ) CT( 

  ﻛﺪ ﺧﻄﺎ ﻋﻨﻮﺍﻥ  ﻋﻠﺖ ﺧﻄﺎ  ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ 

40

 CTﺍﺭﻭﺭ ﺳﻨﺴﻮﺭ   ﺑﺎﺯ ﻳﺎ ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ

  • ﺳﻮﺧﺘﮕﻲ ﻗﺴﻤﺖ ﺣﺴﮕﺮ ﻣﺪﺍﺭ ﺑﺮﺩ
  • ﺑﺮﺭﺳﻲ ﻛﺎﻧﻜﺘﻮﺭ ﺑﺮﻕ ﻭﺭﻭﺩﻱ, ﻣﺪﺍﺭ ﺣﺴﮕﺮ ﺟﺮﻳﺎﻥ ﺧﺮﻭﺟﻲ ﻛﻤﭙﺮﺳﻮﺭ 

. ﻣﺤﻞ ﻗﺮﺍﺭﮔﻴﺮﻱ ﺳﻨﺴﻮﺭ 1 ﺩﻫﺶ 

    ﻣﻘﺩﺍﺭ : 200kΩ ± 10% 

 c°25ﺩﺭ ﺩﻣﺎی

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 40

 

 

 

 

ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ ! 

 

  <ﭼﮕﻮﻧﮕﻲ  ﺑﺮﺭﺳﻲ ﺣﺴﮕﺮ ﺟﺮﻳﺎﻥ ﻭﺭﻭﺩﻱ ﻭ ﺟﺮﻳﺎﻥ ﻓﺎﺯﻱ CH40 ﺍﺭﻭﺭ

  standby ﺩﺭ ﺣﺎﻟﺖ ﺍﺗﺼﺎﻝ ﺑﺮﻕ ﻭ ﺣﺎﻟﺖ DCﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻭﻟﺘﺎژ    ﻗﺮﺍﺭ ﺩﻫﻴﺪDC .ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﺭﻧﺞ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻭﻟﺘﺎژ 1

 

 

 

 

 

 

 

 ! ﺑﺮﺍﻱ ﭼﻚ ﻛﺮﺩﻥ ﺑﺮﺩ ﻳﺎ ﻗﺴﻤﺖ ﻫﺎﻱ ﺍﻟﻜﺘﺮﻳﻜﻲ ﺩﻳﮕﺮ  ﺑﻌﺪ ﺍﺯ ﺧﺎﻣﻮﺵ ﻛﺮﺩﻥ , . 3ﺩﺳﺘﮕﺎﻩ  ﺩﻗﻴﻘﻪ ﺻﺒﺮ ﻛﻨﻴﺪ ﺩﺭ ﺯﻣﺎﻥ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻫﺎ ﻣﻮﺍﻇﺐ ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﺑﺎ ﻗﺴﻤﺖ  ﻫﺎﻱ ﺩﻳﮕﺮ ﺑﺎﺷﻴﺪ.

41

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 ﺩﺍﺭLEDﻧﻮﻉ ﻳﻚ

 

 

 

  ﻭﻟﺘﺎژ • ﺩﺭ R01N ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ ﺩﺭ ﻫﺮ ﺩﻭ ﺳﺮ ﺍﺯ DC : standby  ﺩﺭ ﺍﺗﺼﺎﻝ ﺑﺮﻕ ﺗﻐﺬﻳﻪ  ﻭ ﺩﺭ ﺣﺎﻟﺖ 1ﺷﻜﻞ ﺑﺎﻳﺪ . 2/7 ﺍﻟﻲ 2/3 ﺑﺎﺷﺪ 

 ﺩﺭ ﺣﺎﻟﺖ ﺍﺗﺼﺎﻝ 2 ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺩﺭ ﺷﻜﻞ DC ﻣﻘﺪﺍﺭ ﻭﻟﺘﺎژ • ﻭﻟﺖ 2/7 ﺍﻟﻲ 2/3 ﺑﺎﻳﺪ standbyﺑﺮﻕ ﺗﻐﺬﻳﻪ ﻭ ﺩﺭ ﺣﺎﻟﺖ ﺑﺎﺷﺪ. 

 

  ﺩﺍﺭLEDﻧﻮﻉ ﺩﻭ 

 

 

 

 

 

   ﻭﻟﺘﺎژ •  ﺩﺭ ﺍﺗﺼﺎﻝ ﺑﺮﻕ ﺗﻐﺬﻳﻪ  ﻭ ﺩﺭ ﺣﺎﻟﺖ 1 ﺩﺭ ﺷﻜﻞ R01N ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ ﺩﺭ ﻫﺮ ﺩﻭ ﺳﺮ ﺍﺯ DC standby   : . 2/7 ﺍﻟﻲ 2/3 ﺑﺎﻳﺪ  ﻭﻟﺖ ﺑﺎﺷﺪ   ﺍﻟﻲ 2/3 ﺑﺎﻳﺪ standby ﺩﺭ ﺣﺎﻟﺖ ﺍﺗﺼﺎﻝ ﺑﺮﻕ ﺗﻐﺬﻳﻪ ﻭ ﺩﺭ ﺣﺎﻟﺖ 2 ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺩﺭ ﺷﻜﻞ DC ﻣﻘﺪﺍﺭ ﻭﻟﺘﺎژ  • 7/2. ﻭﻟﺖ ﺑﺎﺷﺪ 

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 42

 

CH41, CH44, CH45, CH46, CH47,  / ﺍﺭﻭﺭﻫﺎﻱ ﻣﺮﺑﻮﻁ ﺑﻪ ﺳﻨﺴﻮﺭﻫﺎﻱ ﺩﻣﺎﻳﻲ CH65 

 

  ﻛﺪ ﺧﻄﺎ ﻋﻨﻮﺍﻥ  ﻋﻠﺖ ﺧﻄﺎ  ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ 

CH41

 ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ ﺩﻫﺶ  )ﻛﻤﭙﺮﺳﻮﺭ ﺍﻳﻨﻮﺭﺗﺮ(

  • ﺍﺗﺼﺎﻝ ﻧﺎﺩﺭﺳﺖ •  ﺍﺗﺼﺎﻝ ﺍﺗﺼﺎﻝ ﺑﺎﺯ / ﻛﻮﺗﺎﻩ 
  • ﻭﺿﻌﻴﺖ ﺍﺗﺼﺎﻝ ﺳﻨﺴﻮﺭ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ •  ﻣﻘﺎﻭﻣﺖ ﻧﺮﻣﺎﻝ : 200㏀/at 25℃(77℉)

ﺳﻨﺴﻮﺭ ﺩﻣﺎﻱ ﻫﻮﺍ CH44  

     ﺍﺗﺼﺎﻝ ﻧﺎﺩﺭﺳﺖ • •  ﺍﺗﺼﺎﻝ ﺍﺗﺼﺎﻝ ﺑﺎﺯ / ﻛﻮﺗﺎﻩ 

   ﻭﺿﻌﻴﺖ ﺍﺗﺼﺎﻝ • ﺳﻨﺴﻮﺭ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ  •  ﻣﻘﺎﻭﻣﺖ ﻧﺮﻣﺎﻝ : 10㏀/at 25℃(77℉)

ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ CH45   ﻛﻨﺪﺍﻧﺴﻮﺭ

  • ﺍﺗﺼﺎﻝ ﻧﺎﺩﺭﺳﺖ •  ﺍﺗﺼﺎﻝ ﺍﺗﺼﺎﻝ ﺑﺎﺯ / ﻛﻮﺗﺎﻩ 

   ﻭﺿﻌﻴﺖ ﺍﺗﺼﺎﻝ • ﺳﻨﺴﻮﺭ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ  •  ﻣﻘﺎﻭﻣﺖ ﻧﺮﻣﺎﻝ  : 5㏀/at 25℃(77℉)

ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ ﻣﻜﺶ CH46  

  • ﺍﺗﺼﺎﻝ ﻧﺎﺩﺭﺳﺖ •  ﺍﺗﺼﺎﻝ ﺍﺗﺼﺎﻝ ﺑﺎﺯ / ﻛﻮﺗﺎﻩ 

   ﻭﺿﻌﻴﺖ ﺍﺗﺼﺎﻝ • ﺳﻨﺴﻮﺭ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ  •  ﻣﻘﺎﻭﻣﺖ ﻧﺮﻣﺎﻝ  : 5㏀/at 25℃(77℉)

ﺳﻨﺴﻮﺭ ﻫﻴﺖ ﺳﻴﻨﻚ CH65  

  • ﺍﺗﺼﺎﻝ ﻧﺎﺩﺭﺳﺖ •  ﺍﺗﺼﺎﻝ ﺍﺗﺼﺎﻝ ﺑﺎﺯ / ﻛﻮﺗﺎﻩ 

   ﻭﺿﻌﻴﺖ ﺍﺗﺼﺎﻝ • ﺳﻨﺴﻮﺭ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ  •  ﻣﻘﺎﻭﻣﺖ ﻧﺮﻣﺎﻝ  : 10㏀/at 25℃(77℉)

 

 ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ ﺩﻫﺶ(1)ﻣﺤﻞ ﻗﺮﺍﺭﮔﻴﺮﻱ ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ ﻭﺳﻂ ﻛﻨﺪﺍﻧﺴﻮﺭ(2) ﺳﻨﺴﻮﺭ ﻫﻮﺍﻱ (3) ﻭﺭﻭﺩﻱ 

43

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

2kW Controller(UL,UL2)

 

1.5kw Controller(UA3)

 

 

 

 

 

 

 

 

ﻭﺭﻭﺩﻱ – ﻣﺤﻞ ﻗﺮﺍﺭﮔﻴﺮﻱ ﺳﻨﺴﻮﺭ ﻫﺎﻱ ﺩﻫﺶ ﻛﻤﭙﺮﺳﻮﺭ-ﻭﺳﻂ ﻛﻨﺪﺍﻧﺴﻮﺭ-ﻣﻜﺶ ﻛﻤﭙﺮﺳﻮﺭ ﻫﻮﺍ

 

 

 

 

 

4kw Controller(UE,UE1)

 

 

)1) (3) (2(

)3) (2) (1(

)1 ( )2 ( )3(

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 44

 

 

 

 

 

 

 

ﻣﺤﻞ ﻗﺮﺍﺭﮔﻴﺮﻱ :ﺑﻴﺮﻭﻥ ﺍﺯ ﻛﻤﭙﺮﺳﻮﺭ

45

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

ﺟﺪﻭﻝ ﺩﻣﺎ-ﻣﻘﺎﻭﻣﺖ  :ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ ﺩﻫﺶ/ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ/ﺳﻨﺴﻮﺭ ﻫﻮﺍ/ﺳﻨﺴﻮﺭ ﻫﻴﺖ ﺳﻴﻨﻚ 

ﺩﻣﺎ (℃/℉)

ﻣﻘﺎﻭﻣﺖ( ㏀)

ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ ﺩﻫﺶ

ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ 

ﺳﻨﺴﻮﺭ ﻫﻮﺍ 

ﺳﻨﺴﻮﺭ ﻫﻴﺖ ﺳﻴﻨﻚ 

-30/-22 2845.99 102.17 204.35 102.17

 

-25/-13  73.49 146.97 73.49

 

-20/-4  53.55 107.09 53.55

 

-15/5  3950 79.00 39.50

 

-10/14  29.48 58.95 29.48

 

-5/23  22.24 44.47 22.24

 

0/32 585.66 16.95 33.90 16.95

 

5/41 465.17 13.05 26.09 26.05

 

10/50 372.49 10.14 20.27 20.25

 

15/59 300.58 7.94 15.89 15.87

 

20/68 244.33 6.28 12.55 12.55

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 46

 

25/77 200.00 5.00 10.00 10.00

 

30/86 164.79 4.01 8.03 8.03

 

35/95 136.64 3.24 6.49 6.49

 

40/104 113.98 2.64 5.28 5.28

 

45/113 95.62 2.16 4.32 4.33

 

50/122 80.65 1.78 3.56 3.57

 

55/131 68.38 1.48 2.95 2.96

 

60/140 58.27 1.23 2.46 2.47

 

65/149 49.88 1.03 2.06 2.07

 

70/158 42.90 0.87 1.74 1.74

 

75/167 37.05 0.74 1.47 1.48

 

80/176 32.14 0.63 1.25 1.26

 

90/194 24.46 0.46 0.92 0.92

 

100/212 18.89 0.34 0.68 0.69

 

 

47

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

( –ﻣﻘﺎﻭﻣﺖ  ﺩﻣﺎﻱ ﺳﻨﺴﻮﺭ ) ﻧﺮﻣﺎﻝ

ﺩﻣﺎ  (℃/℉) ﻣﻘﺎﻭﻣﺖ (㏀) ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ ﺩﻫﺶ  ﺳﻨﺴﻮﺭ ﻫﻮﺍ ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ   

ﺳﻨﺴﻮﺭ ﻫﻴﺖ ﺳﻴﻨﻚ 

25/77 200.00 5.00 10.00 10.00

 

 

   <ﺍﺭﻭﺭ ﺍﺭﺗﺒﺎﻃﻲ ﻭﺍﺣﺪ ﺑﻴﺮﻭﻧﻲ CH53 ﺍﺭﻭﺭ

 ﻛﺪ ﺧﻄﺎ ﻋﻨﻮﺍﻥ ﻋﻠﺖ ﺧﻄﺎ ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ

 

CH53

ﺍﺭﺗﺒﺎﻁ ﻭﺍﺣﺪ ﺩﺍﺧﻠﻲ ﻭ ﺑﻴﺮﻭﻧﻲ -ﺩﻳﺘﺎﻱ ﺍﺭﺳﺎﻟﻲ ﺍﺯ ﻭﺍﺣﺪ ﺩﺍﺧﻠﻲ ﺑﻪ  ﺩﻗﻴﻘﻪ 3ﻣﺪﺕ ﺩﺭﻳﺎﻓﺖ ﻧﺸﻮﺩ 

 ﺑﺮﻕ ﻭﺍﺣﺪ ﺩﺍﺧﻠﻲ  ﻳﺎ ﺑﻴﺮﻭﻧﻲ • ﺍﻳﺮﺍﺩ ﺩﺍﺭﺩ  ﺍﺭﺗﺒﺎﻁ ﺑﻴﻦ ﺩﺍﺧﻠﻲ ﻭ ﺑﻴﺮﻭﻧﻲ • ﺑﻪ ﻭﺳﻴﻠﻪ ﻳﻚ ﻧﻮﻳﺰ ﺑﻴﺮﻭﻧﻲ ﻣﺨﺘﻞ ﺷﺪﻩ  ﻗﻄﻌﺎﺕ ﺍﺭﺗﺒﺎﻃﻲ ﺑﻴﻦ ﻭﺍﺣﺪ • ﺩﺍﺧﻠﻲ ﻭ ﺑﻴﺮﻭﻧﻲ ﺳﻮﺧﺘﻪ ﺑﺎﺷﻨﺪ

 ﺑﺮﻕ ﻭﺍﺣﺪ ﺩﺍﺧﻠﻲ ﺭﺍ ﺑﺮﺭﺳﻲ • ﻛﻨﻴﺪ  ﺑﺮﻕ ﻭﺭﻭﺩﻱ ﺑﻪ ﻭﺍﺣﺪ ﺑﻴﺮﻭﻧﻲ • ﻭ ﺩﺍﺧﻠﻲ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ  ﺍﺗﺼﺎﻝ ﺯﻣﻴﻦ ﻭﺍﺣﺪ ﺩﺍﺧﻠﻲ ﻭ • ﺑﻴﺮﻭﻧﻲ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ  ﻗﻄﻌﺎﺕ ﺍﺭﺗﺒﺎﻃﻲ ﺑﻴﻦ ﻭﺍﺣﺪ • ﺩﺍﺧﻠﻲ ﻭ ﺑﻴﺮﻭﻧﻲ ﺭﺍ ﺍﺯ ﻧﻈﺮ ﺳﻮﺧﺘﮕﻲ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ 

ﺩﺭ ﺗﻤﺎﻣﻲ ﺍﺭﻭﺭﻫﺎ:

ﺯﻣﺎﻧﻲ ﻛﻪ ﻫﻤﻪ ﻣﺮﺍﺣﻞ ﺑﺮﺭﺳﻲ ﺍﻧﺠﺎﻡ ﺷﺪ ﻭ ﺑﻪ ﺍﻳﻦ ﻧﺘﻴﺠﻪ ﺭﺳﻴﺪﻳﺪ ﻛﻪ ﺑﺮﺩ ﺭﺍ ﺗﻌﻮﻳﺾ ﻛﻨﻴﺪ , ﻗﺒﻞ ﺍﺯ ﺗﻌﻮﻳﺾ ﺑﺮﺩ ﺍﻗﺪﺍﻣﺎﺕ ﺯﻳﺮ ﺭﺍ ﺣﺘﻤﺎ ﺍﻧﺠﺎﻡ ﺩﻫﻴﺪ : 1 (ﺑﺮﻕ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﻗﻄﻊ ﻛﻨﻴﺪ 2 (ﺗﻤﺎﻣﻲ ﻛﺎﻧﻜﺘﻮﺭﻫﺎﻱ ﺑﺮﺩ ﺑﻴﺮﻭﻧﻲ ﻭ ﺑﺮﺩ  ﺩﺍﺧﻠﻲ ﺭﺍ ﺍﺯ ﺭﻭﻱ ﺑﺮﺩ ﺟﺪﺍ ﻛﻨﻴﺪ 3 (ﭼﻨﺪ ﺩﻗﻴﻘﻪ ﺻﺒﺮ ﻛﻨﻴﺪ

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 48

 

4 (ﺳﭙﺲ ﺗﻤﺎﻣﻲ ﻛﺎﻧﻜﺘﻮﺭ ﻫﺎ ﺭﺍ ﺩﻭﺑﺎﺭﻩ ﻭﺻﻞ ﻛﻨﻴﺪ 5 (. ﺑﺮﻕ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﺩﻭﺑﺎﺭﻩ ﻭﺻﻞ ﻛﻨﻴﺪ ﻭ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﺭﻭﺷﻦ ﻛﻨﻴﺪ ﺩﺭ ﺻﻮﺭﺕ ﺑﺮﻭﺯ ﺩﻭﺑﺎﺭﻩ ﺍﺭﻭﺭ ﻧﺴﺒﺖ ﺑﻪ ﺗﻌﻮﻳﺾ ﺑﺮﺩ ﺍﻗﺪﺍﻡ ﻧﻤﺎﺋﻴﺪ.

 

 

49

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

 

 

 

ﺍﺭﻭﺭ CH60 ﺍﺭﻭﺭ ) EEPROM( 

  ﻛﺪ ﺧﻄﺎ ﻋﻨﻮﺍﻥ  ﻋﻠﺖ ﺧﻄﺎ  ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ 

ﺑﺮﺭﺳﻲ CH60 EEPROM

  • ﺧﺮﺍﺑﻲ ﻳﺎ ﻧﺒﻮﺩﻥ ﺑﺮﺩ ﺑﻴﺮﻭﻧﻲEEPROM EEPROM  ﺍﺗﺼﺎﻝ ﺑﺪ • ﺑﺮﺩ ﻭﺍﺣﺪ ﺑﻴﺮﻭﻧﻲ 

: EEPROMﺑﺮﺭﺳﻲ  ﺍﺯ ﻧﻈﺮ   ﻣﻮﺟﻮﺩ ﺑﻮﺩﻥ   ﺍﺗﺼﺎﻝ ﺩﺭﺳﺖ   ﺧﺮﺍﺏ ﻧﺒﻮﺩﻥ  ﻫﻤﺨﻮﺍﻧﻲ ﺩﺍﺷﺘﻦ ﺑﺎ  ﺩﺳﺘﮕﺎﻩ

 

 

 

 

 

 ﺑﻌﺪ ﺍﺯ ﺧﺎﻣﻮﺵ ، ﺑﺮﺍﻱ ﭼﻚ ﻛﺮﺩﻥ ﺑﺮﺩ ﻳﺎ ﻗﺴﻤﺖ ﻫﺎﻱ ﺍﻟﻜﺘﺮﻳﻜﻲ ﺩﻳﮕﺮ . 3ﻛﺮﺩﻥ ﺩﺳﺘﮕﺎﻩ  ﺩﻗﻴﻘﻪ ﺻﺒﺮ ﻛﻨﻴﺪ ﺩﺭ ﺯﻣﺎﻥ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻫﺎ  ﻣﻮﺍﻇﺐ ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﺑﺎ ﻗﺴﻤﺖ ﻫﺎﻱ ﺩﻳﮕﺮ ﺑﺎﺷﻴﺪ. 

 

 

 

 !

 

 

 ﺑﻌﺪ ﺍﺯ ، ! ﺑﺮﺍﻱ ﭼﻚ ﻛﺮﺩﻥ ﺑﺮﺩ ﻳﺎ ﻗﺴﻤﺖ ﻫﺎﻱ ﺍﻟﻜﺘﺮﻳﻜﻲ ﺩﻳﮕﺮ . 3ﺧﺎﻣﻮﺵ ﻛﺮﺩﻥ ﺩﺳﺘﮕﺎﻩ  ﺩﻗﻴﻘﻪ ﺻﺒﺮ ﻛﻨﻴﺪ ﺩﺭ ﺯﻣﺎﻥ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻫﺎ ﻣﻮﺍﻇﺐ ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﺑﺎ ﻗﺴﻤﺖ ﻫﺎﻱ ﺩﻳﮕﺮ ﺑﺎﺷﻴﺪ.

 ﮔﻢ ﺷﺪﻩ EEPROMﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ ﺍﮔﺮ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ ﻭﺿﻌﻴﺖ ﻗﺮﺍﺭﮔﻴﺮﻱ EEPROM

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 50

 

: EEPROMﺑﺮﺭﺳﻲ ﻭﺿﻌﻴﺖ ﻗﺮﺍﺭ ﮔﻴﺮﻱ  ﻭﺍﺣﺪ ﺑﻴﺮﻭﻧﻲ      ﻭ ﺳﻮﻛﺖ ﺁﻥ ﺩﺭﺳﺖ ﺑﺎﺷﺪEEPROM .ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ ﺟﻬﺖ 1   ﺑﻪ ﺻﻮﺭﺕ ﻛﺎﻣﻞ ﻭ ﺩﺭﺳﺖ ﺩﺭ ﺳﻮﻛﺖ ﻗﺮﺍﺭ ﺩﺍﺷﺘﻪ ﺑﺎﺷﺪEEPROM .ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ 2   ﺩﺭ ﺳﻮﻛﺖ ﻗﺮﺍﺭ ﺩﺍﺷﺘﻪ ﺑﺎﺷﻨﺪEEPROM .ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ ﺗﻤﺎﻡ ﭘﺎﻳﻪ ﻫﺎﻱ 3

  ﺩﺍﺭLED 2ﻧﻮﻉ

 

 ﺩﺍﺭLED 1ﻧﻮﻉ

 

 

 

( CH 61 ﺍﺭﻭﺭ   )ﺍﺭﻭﺭ ﺩﻣﺎﻱ ﺑﺎﻻﻱ ﻟﻮﻟﻪ ﻛﻨﺪﺍﻧﺴﻮﺭ 

  ﻛﺪ ﺧﻄﺎ ﻋﻨﻮﺍﻥ  ﻋﻠﺖ ﺧﻄﺎ  ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ

 

CH61

ﺩﻣﺎﻱ ﺑﺎﻻﻱ ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ   ﻛﻨﺪﺍﻧﺴﻮﺭ (63℃(145 ℉)

--ﻓﻦ ﺑﻴﺮﻭﻧﻲ  – )ﺣﺎﻟﺖ ﺍﻭﺭ ﻟﻮﺩ ﺧﺮﺍﺑﻲ /ﺟﻬﺖ ﻭﺯﺵ ﺑﺎﺩ /ﻗﻔﻞ ﺷﺪﮔﻲ ﻭ ...(  - ﻛﺜﻴﻔﻲ ﻛﻮﻳﻞ ﻛﻨﺪﺍﻧﺴﻮﺭ   ﻭ ﺳﻮﻛﺖ ﺁﻥ ﻭ ﻭﺿﻌﻴﺖ EEVﻗﺮﺍﺭﮔﻴﺮﻱ ﺁﻥ  - ﺧﺮﺍﺑﻲ ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ ﻛﻨﺪﺍﻧﺴﻮﺭ ﻳﺎ ﺍﺗﺼﺎﻝ ﻧﺎﺩﺭﺳﺖ ﺁﻥ 

  ﻓﻦ ﺑﻴﺮﻭﻧﻲ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ•  ﻣﻴﺰﺍﻥ ﻣﺒﺮﺩ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ• ﺭﺍ ﺑﺮﺭﺳﻲ EEV ﻭﺿﻌﻴﺖ • ﻛﻨﻴﺪ  ﻭﺿﻌﻴﺖ ﻗﺮﺍﺭﮔﻴﺮﻱ • ﺳﻨﺴﻮﺭ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ

 

 

51

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

 

 

 

 

 

ﺑﺮﺍﻱ ﭼﻚ ﻛﺮﺩﻥ ﺑﺮﺩ ﻳﺎ ﻗﺴﻤﺖ ﻫﺎﻱ ﺍﻟﻜﺘﺮﻳﻜﻲ ﺩﻳﮕﺮ , ﺑﻌﺪ ﺍﺯ ﺧﺎﻣﻮﺵ ﺩﺭ ﺯﻣﺎﻥ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻫﺎ ﻣﻮﺍﻇﺐ 3ﻛﺮﺩﻥ ﺩﺳﺘﮕﺎﻩ  ﺩﻗﻴﻘﻪ ﺻﺒﺮ ﻛﻨﻴﺪ. ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﺑﺎ ﻗﺴﻤﺖ ﻫﺎﻱ ﺩﻳﮕﺮ ﺑﺎﺷﻴﺪ. 

 

 

 

 !

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 52

 

  ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ ﻛﻨﺪﺍﻧﺴﻮﺭ 

 ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻣﻘﺎﻭﻣﺖ  ﻗﺮﺍﺭ ﺩﻫﻴﺪ ﻣﻘﺎﻭﻣﺖ ﭘﻴﻦ ﻫﺎﻱ ﺳﻨﺴﻮﺭ ﺭﺍ ﺍﻧﺪﺍﺯﻩ ﺑﮕﻴﺮﻳﺪ  ﺩﺭﺻﺪ ﺗﻠﺮﺍﻧﺲ ﻣﻲ ﺑﺎﺷﺪ ﺍﮔﺮ ﻣﻘﺎﻭﻣﺖ ﺳﻨﺴﻮﺭ ﺩﺭﺳﺖ ﻧﺒﻮﺩ 10  ﺩﺭ ﺟﻪ ﺑﺎ 25 ﻛﻴﻠﻮ ﺍﻫﻢ  ﺩﺭ ﺩﻣﺎﻱ 5ﻣﻘﺪﺍﺭ ﻣﺠﺎﺯ ﻣﻘﺪﺍﺭ  ﻣﻘﺎﻭﻣﺖ ﺁﻥ ﺭﺍ ﺑﺎ ﻟﻮﻟﻪ ﺩﺳﺘﮕﺎﻩ ﺍﻧﺪﺍﺯﻩ ﺑﺎﻳﺪ ﺑﻴﺸﺘﺮ ﺍﺯ ( 1 )ﺑﮕﻴﺮﻳﺪ ﻣﮕﺎ  ﺍﻫﻢ ﺑﺎﺷﺪ 

 

 

( CH 62ﺍﺭﻭﺭ  )ﺍﺭﻭﺭ ﺩﻣﺎﻱ ﺑﺎﻻﻱ ﻫﻴﺖ ﺳﻴﻨﻚ 

ﻛﺪ ﺧﻄﺎ

ﻋﻨﻮﺍﻥ ﻋﻠﺖ ﺧﻄﺎ ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ

 ﺩﻣﺎﻱ ﺑﺎﻻﻱ ﺑﺮﺩ ﻫﻴﺖ CH62 ﺳﻴﻨﻚ ﺑﻴﺮﻭﻧﻲ

 -ﻓﻦ ﺑﻴﺮﻭﻧﻲ  ﺧﺮﺍﺑﻲ – )ﺣﺎﻟﺖ ﺍﻭﺭ ﻟﻮﺩ /ﺟﻬﺖ ﻭﺯﺵ ﺑﺎﺩ /ﻗﻔﻞ ﺷﺪﮔﻲ ﻭ ...(     ﻧﺼﺐ ﻧﺎﺩﺭﺳﺖ ﻫﻴﺖ ﺳﻴﻨﻚ•   ﺍﻳﺮﺍﺩ ﺍﺯ ﻗﺴﻤﺖ ﺣﺴﮕﺮ ﺩﻣﺎﻱ ﺑﺮﺩ•

 

 ﻓﻦ ﺑﻴﺮﻭﻧﻲ ﺭﺍ ﺑﺮﺭﺳﻲ • ﻛﻨﻴﺪ   ﻭﺿﻌﻴﺖ ﺍﺗﺼﺎﻝ ﻫﻴﺖ • ﺳﻴﻨﻚ ﺑﺮﺩ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ   ﻗﺴﻤﺖ ﺣﺴﮕﺮ ﺩﻣﺎﻱ ﺑﺮﺩ • ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ 

 

 

 

53

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

 

 

 

 

ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ ! 

 

ﻧﻜﺘﻪ ﻣﻬﻢ :

ﻫﺮ ﺯﻣﺎﻧﻲ ﻛﻪ ﺑﺮﺩ ﺭﺍ ﺍﺯ ﻫﻴﺖ ﺳﻴﻨﻚ ﺟﺪﺍ ﻛﺮﺩﻳﺪ ﺑﺎﻳﺪ ﺍﺯ ﺧﻤﻴﺮ ﺳﻴﻠﻴﻜﻮﻧﻲ ﺗﺎﺯﻩ  ﺑﺮﺍﻱ ﺯﻳﺮ ﻫﻴﺖ ﺳﻴﻨﻚ ﺍﺳﺘﻔﺎﺩﻩ ﺷﻮﺩ. 

 

 ﺑﻌﺪ ﺍﺯ ﺧﺎﻣﻮﺵ ،ﺑﺮﺍﻱ ﭼﻚ ﻛﺮﺩﻥ ﺑﺮﺩ ﻳﺎ ﻗﺴﻤﺖ ﻫﺎﻱ ﺍﻟﻜﺘﺮﻳﻜﻲ ﺩﻳﮕﺮ ﺩﺭ ﺯﻣﺎﻥ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻫﺎ ﻣﻮﺍﻇﺐ 3ﻛﺮﺩﻥ ﺩﺳﺘﮕﺎﻩ  ﺩﻗﻴﻘﻪ ﺻﺒﺮ ﻛﻨﻴﺪ. ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﺑﺎ ﻗﺴﻤﺖ ﻫﺎﻱ ﺩﻳﮕﺮ ﺑﺎﺷﻴﺪ. 

 

 

 

 !

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 54

 

  ﭼﮕﻮﻧﻪ ﺩﻣﺎﻱ ﺑﺮﺩ ﺭﺍ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻛﻨﻴﻢCH 62 < > ﺍﺭﻭﺭ

ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻣﻘﺎﻭﻣﺖ ﺳﻨﺴﻮﺭ ﺩﻣﺎﻱ ﺑﺮﺩ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 ﺳﻨﺴﻮﺭ ﺩﻣﺎﻱ ﻫﻴﺖ ﺳﻴﻨﻚ

 ﺩﺍﺭLED 1ﻣﺪﻝ

 

 PSC/PFC   ﺍﻧﺪﺍﺯﻩ ﻣﻘﺎﻭﻣﺖ ﺑﻴﻦ •  ﺩﺭ ﺣﺎﻟﺖ ﻗﻄﻊ ﺑﻮﺩﻥ ﺑﺮﻕ19~20 ﭘﺎﻳﻪ ﻫﺎﻱ 7 ﻣﻴﺰﺍﻥ ﻣﻘﺎﻭﻣﺖ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ • ﺩﺭ ㏀±10%, ﺩﻣﺎﻱ  25℃

 

ﻛﺎﻧﻜﺘﻮﺭ ﻫﻴﺖ ﺳﻴﻨﻚ )ﻛﺎﻧﻜﺘﻮﺭ ﺳﻔﻴﺪ ﺩﻭ ﺳﻴﻢ ﺩﺍﺭ( 

 

 

 

  ﺩﺭ ﺣﺎﻟﺖ ﻗﻄﻊ ﺑﻮﺩﻥ ﺑﺮﻕ19~20     ﭘﺎﻳﻪ ﻫﺎﻱ PSC/PFC ﺍﻧﺪﺍﺯﻩ ﻣﻘﺎﻭﻣﺖ ﺑﻴﻦ •

  • 7 ﻣﻴﺰﺍ ﻥ ﻣﻘﺎﻭﻣﺖ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ ﺩﺭ ﺩﻣﺎﻱ ㏀±10%, 25℃

 

55

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

( CH67ﺍﺭﻭﺭ  )ﺍﺭﻭﺭ ﻗﻔﻞ ﺷﺪﻥ ﻓﻦ ﻭﺍﺣﺪ ﺑﻴﺮﻭﻧﻲ 

  ﻛﺪ ﺧﻄﺎ ﻋﻨﻮﺍﻥ  ﻋﻠﺖ ﺧﻄﺎ  ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ 

CH67

ﺳﻴﮕﻨﺎﻝ ﺑﺮﮔﺸﺘﻲ )ﻓﻴﺪﺑﻚ(ﻛﺎﺭ ﻛﺮﺩ ﻓﻦ BLDC ﻭﺟﻮﺩ ﻧﺪﺍﺭﺩ 

 -ﻓﻦ ﺑﻴﺮﻭﻧﻲ ﻗﻔﻞ ﺷﺪﻩ ﺑﺎﺷﺪ   -ﻛﺎﻧﻜﺘﻮﺭ ﻓﻦ ﺭﻭﻱ ﺑﺮﺩ ﺟﺪﺍ ﺷﺪﻩ ﺑﺎﺷﺪ   -ﻣﻮﺗﻮﺭ ﻓﻦ ﺳﻮﺧﺘﻪ ﺑﺎﺷﺪ ﻳﺎ ﻓﻴﻮﺯﺁﻥ ﺳﻮﺧﺘﻪ ﺑﺎﺷﺪ   -ﻣﺪﺍﺭ ﻛﺎﺭﻛﺮﺩ ﻓﻦ ﺩﺭ ﺑﺮﺩ ﺁﺳﻴﺐ ﺩﻳﺪﻩ ﺑﺎﺷﺪ 

 ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ ﻭﺿﻌﻴﺖ • ﻗﺮﺍﺭﮔﻴﺮﻱ ﻓﻦ ﺑﻴﺮﻭﻧﻲ ﺭﺍ   ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ ﻭﺿﻌﻴﺖ • ﻛﺎﻧﻜﺘﻮﺭ ﻓﻦ ﺑﻴﺮﻭﻧﻲ ﺭﺍ ﺑﺮ ﺭﻭﻱ ﺑﺮﺩ   ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ ﺳﻴﻢ ﻓﻦ ﻭ ﻓﻴﻮﺯ • ﺁﻥ ﺭﺍ   ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ ﻓﻦ ﺭﺍ ﺍﺯ ﻧﻈﺮ • ﺳﻮﺧﺘﮕﻲ 

 

 

 

 

 

 

 

 

 

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 56

 

ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ ! 

 

 

ﺩﺭ ﺗﻤﺎﻣﻲ ﺍﺭﻭﺭﻫﺎ:

 ،ﺯﻣﺎﻧﻲ ﻛﻪ ﻫﻤﻪ ﻣﺮﺍﺣﻞ ﺑﺮﺭﺳﻲ ﺍﻧﺠﺎﻡ ﺷﺪ ﻭ ﺑﻪ ﺍﻳﻦ ﻧﺘﻴﺠﻪ ﺭﺳﻴﺪﻳﺪ ﻛﻪ ﺑﺮﺩ ﺭﺍ ﺗﻌﻮﻳﺾ ﻛﻨﻴﺪ ﻗﺒﻞ ﺍﺯ ﺗﻌﻮﻳﺾ ﺑﺮﺩ ﺍﻗﺪﺍﻣﺎﺕ ﺯﻳﺮ ﺭﺍ ﺣﺘﻤﺎ ﺍﻧﺠﺎﻡ ﺩﻫﻴﺪ : 1 (ﺑﺮﻕ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﻗﻄﻊ ﻛﻨﻴﺪ 2 (ﺗﻤﺎﻣﻲ ﻛﺎﻧﻜﺘﻮﺭﻫﺎﻱ ﺑﺮﺩ ﺑﻴﺮﻭﻧﻲ ﻭ ﺑﺮﺩ ﺩﺍﺧﻠﻲ ﺭﺍ ﺍﺯ ﺭﻭﻱ ﺑﺮﺩ ﺟﺪﺍ ﻛﻨﻴﺪ 3 (ﭼﻨﺪ ﺩﻗﻴﻘﻪ ﺻﺒﺮ ﻛﻨﻴﺪ

57

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

4 (ﺳﭙﺲ ﺗﻤﺎﻣﻲ ﻛﺎﻧﻜﺘﻮﺭ ﻫﺎ ﺭﺍ ﺩﻭﺑﺎﺭﻩ ﻭﺻﻞ ﻛﻨﻴﺪ 5 (. ﺑﺮﻕ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﺩﻭﺑﺎﺭﻩ ﻭﺻﻞ ﻛﻨﻴﺪ ﻭ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﺭﻭﺷﻦ ﻛﻨﻴﺪ ﺩﺭ ﺻﻮﺭﺕ ﺑﺮﻭﺯ ﺩﻭﺑﺎﺭﻩ ﺍﺭﻭﺭ ﻧﺴﺒﺖ ﺑﻪ ﺗﻌﻮﻳﺾ ﺑﺮﺩ ﺍﻗﺪﺍﻡ ﻧﻤﺎﺋﻴﺪ.

   ﻳﻮﻧﻴﺖ ﺑﻴﺮﻭﻧﻲBLDCﺑﺮﺭﺳﻲ ﺳﻮﺧﺘﮕﻲ ﻣﻮﺗﻮﺭ ﻓﻦ

 

 

 

 

 

ﺩﺭ ﺗﻤﺎﻣﻲ ﺍﺭﻭﺭﻫﺎ:

 ،ﺯﻣﺎﻧﻲ ﻛﻪ ﻫﻤﻪ ﻣﺮﺍﺣﻞ ﺑﺮﺭﺳﻲ ﺍﻧﺠﺎﻡ ﺷﺪ ﻭ ﺑﻪ ﺍﻳﻦ ﻧﺘﻴﺠﻪ ﺭﺳﻴﺪﻳﺪ ﻛﻪ ﺑﺮﺩ ﺭﺍ ﺗﻌﻮﻳﺾ ﻛﻨﻴﺪ ﻗﺒﻞ ﺍﺯ ﺗﻌﻮﻳﺾ ﺑﺮﺩ ﺍﻗﺪﺍﻣﺎﺕ ﺯﻳﺮ ﺭﺍ ﺣﺘﻤﺎ ﺍﻧﺠﺎﻡ ﺩﻫﻴﺪ : ﺑﺮﻕ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﻗﻄﻊ ﻛﻨﻴﺪ ﺗﻤﺎﻣﻲ ﻛﺎﻧﻜﺘﻮﺭﻫﺎﻱ ﺑﺮﺩ ﺑﻴﺮﻭﻧﻲ ﻭ ﺑﺮﺩ ﺩﺍﺧﻠﻲ ﺭﺍ ﺍﺯ ﺭﻭﻱ ﺑﺮﺩ ﺟﺪﺍ ﻛﻨﻴﺪ ﭼﻨﺪ ﺩﻗﻴﻘﻪ ﺻﺒﺮ ﻛﻨﻴﺪ ﺳﭙﺲ ﺗﻤﺎﻣﻲ ﻛﺎﻧﻜﺘﻮﺭ ﻫﺎ ﺭﺍ ﺩﻭﺑﺎﺭﻩ ﻭﺻﻞ ﻛﻨﻴﺪ ﺑﺮﻕ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﺩﻭﺑﺎﺭﻩ ﻭﺻﻞ ﻛﻨﻴﺪ ﻭ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﺭﻭﺷﻦ ﻛﻨﻴﺪ. ﺩﺭ ﺻﻮﺭﺕ ﺑﺮﻭﺯ ﺩﻭﺑﺎﺭﻩ ﺍﺭﻭﺭ ﻧﺴﺒﺖ ﺑﻪ ﺗﻌﻮﻳﺾ ﺑﺮﺩ ﺍﻗﺪﺍﻡ ﻧﻤﺎﺋﻴﺪ.

 

 ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻛﻨﻴﺪ ﻭﻟﺘﺎژ ﺑﻴﻦ ﭘﻴﻦ •  ﺭﺍ ﺩﺭ ﺣﺎﻟﺖ ﻗﻄﻊ ﺑﺮﻕ 4 ﻭ 1ﻫﺎﻱ 1V   ﺍﮔﺮ ﻭﻟﺘﺎژ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ• ﺑﺎﺷﺪ ﻣﻮﺗﻮﺭ ﺍﺯ ﺩﺍﺧﻞ ±0.2V ﺳﻮﺧﺘﻪ ﺍﺳﺖ 

  

 

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 58

 

ﺭﻭﺵ ﻫﺎﻱ ﺑﺮﺭﺳﻲ  ﭼﮕﻮﻧﮕﻲ ﺑﺮﺭﺳﻲ ﺷﺮﺍﻳﻂ ﻧﺼﺐ ﻭﺍﺣﺪ ﺑﻴﺮﻭﻧﻲ 

  ﻋﻠﺖ ﻣﻮﻗﻌﻴﺖ  ﺍﻳﺮﺍﺩ ﻇﺎﻫﺮﻱ 

ﺣﺎﻟﺖ ﮔﺮﺩﺑﺎﺩ 

-ﻣﺴﺪﻭﺩ ﺷﺪﻥ ﻗﺴﻤﺖ ﺟﻠﻮﻳﻲ ﻭﺍﺣﺪ ﺑﻴﺮﻭﻧﻲ -ﻓﻀﺎﻱ ﻧﺼﺐ ﻭﺍﺣﺪ ﺑﻴﺮﻭﻧﻲ ﺑﺎﺭﻳﻚ ﺑﺎﺷﺪ 

  ﺑﺮﮔﺸﺖ ﻣﻜﺮﺭ ﻫﻮﺍﻱ ﮔﺮﻡ ﺑﻪ ﺩﺍﺧﻞ ﺩﺳﺘﮕﺎﻩ ﻭ ﺧﺎﻣﻮﺵ ﺷﺪﻥ ﻛﻤﭙﺮﺳﻮﺭ   Over Loadﺩﺳﺘﮕﺎﻩ ﺩﭼﺎﺭ ﻣﻲ ﺷﻮﺩ 

ﻣﺴﺪﻭﺩ ﺷﺪﻥ ﺟﺮﻳﺎﻥ ﻫﻮﺍ 

 ﻗﺴﻤﺖ ﭘﻬﻠﻮﻱ ﺩﺳﺘﮕﺎﻩ ﺑﻴﺮﻭﻧﻲ ﻣﺴﺪﻭﺩ • ﺑﺎﺷﺪ  ﺷﻴﺌﻲ ﺧﺎﺭﺟﻲ  ﻣﺎﻧﻊ ﮔﺮﺩﺵ ﻫﻮﺍﻱ • ﻛﻨﺪﺍﻧﺴﻮﺭ ﺷﺪﻩ ﺑﺎﺷﺪ 

 

 

 ﺑﺎﻻ ﺭﻓﺘﻦ ﺩﻣﺎﻱ ﻟﻮﻟﻪ ﺑﻌﻠﺖ • ﻛﺎﻫﺶ ﺳﺮﻋﺖ ﻫﻮﺍ ﻭ ﺧﺎﻣﻮﺷﻲ ﻣﻜﺮﺭ ﻛﻤﭙﺮﺳﻮﺭ  Over Loadﺩﺳﺘﮕﺎﻩ ﺩﭼﺎﺭ ﻣﻲ ﺷﻮﺩ 

ﺧﻮﺭﺩﮔﻲ 

  ﻧﻢ– ﺭﻃﻮﺑﺖ • ﺭﻃﻮﺑﺖ ﺑﺎﻻﻱ ﻣﺤﻴﻂ•

  ﺧﻮﺭﺩﮔﻲ ﻛﻨﺪﺍﻧﺴﻮﺭ • ﻛﺎﻫﺶ ﺑﺎﺯﺩﻫﻲ ﺩﺳﺘﮕﺎﻩ 

( 1)  ﺯﻣﺎﻧﻲ ﻛﻪ ﺟﻠﻮ ﻳﺎ ﻋﻘﺐ ﺩﺳﺘﮕﺎﻩ ﺩﻳﻮﺍﺭ ﺑﺎﺷﺪ  ﻃﺮﻑ 

 

 ﭼﭗ ﻳﺎ ﺭﺍﺳﺖ ﺩﺳﺘﮕﺎﻩ ﺩﻳﻮﺍﺭ ﺑﺎﺷﺪ  ( 2) /ﺯﻣﺎﻧﻲ ﻛﻪ ﺟﻠﻮ ﻳﺎ ﻋﻘﺐ ﻃﺮﻑ 

59

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

 

 ﭼﭗ ﻳﺎ ﺭﺍﺳﺖ ﺩﺳﺘﮕﺎﻩ ﺩﻳﻮﺍﺭ ﺑﺎﺷﺪ  ( 3) /ﺯﻣﺎﻧﻲ ﻛﻪ ﺟﻠﻮ ﻳﺎ ﻋﻘﺐ ﻃﺮﻑ 

 

 

ﭼﮕﻮﻧﮕﻲ ﺑﺮﺭﺳﻲ ﺟﺮﻳﺎﻥ ﻣﺒﺮﺩ 

  ﻋﻠﺖ ﻣﻮﻗﻌﻴﺖ  ﺍﻳﺮﺍﺩ ﻇﺎﻫﺮﻱ 

ﻣﺰﺍﺣﻤﺖ ﺩﺭ ﻋﺒﻮﺭ ﺟﺮﻳﺎﻥ ﻣﺒﺮﺩ 

 ﻣﺴﺪﻭﺩ • ﺩﻭ ﭘﻬﻨﻲ  / ﺷﺪﮔﻲ ﻟﻮﻟﻪ ﻛﺸﻲ   EEV ﺍﻳﺮﺍﺩ • ﺑﺴﺘﻪ ﺑﻮﺩﻥ ﺷﻴﺮ • ﺳﺮﻭﻳﺲ

  ﻳﺦ ﺯﺩﮔﻲ ﻭﺍﺣﺪ ﺩﺍﺧﻠﻲ   ﺑﺎﻻ ﺭﻓﺘﻦ ﺑﻴﺶ ﺍﺯ ﺣﺪ ﺩﻣﺎﻱ ﺗﺒﺨﻴﺮ ﻣﺎﺩﻩ ﻣﺒﺮﺩ       ﺳﺮﻣﺎﻳﺶ ﻭ ﮔﺮﻣﺎﻳﺶ ﺿﻌﻴﻒ  ﺟﺮﻳﺎﻥ ﻧﺎﻣﻨﺎﺳﺐ ﻣﺒﺮﺩ  ﺧﺎﻣﻮﺵ ﻭ ﺭﻭﺷﻦ ﺷﺪﻥ ﻣﻜﺮﺭ ﻛﻤﭙﺮﺳﻮﺭ ﺑﺎ  ﺳﻴﺴﺘﻢ ﺣﻔﺎﻇﺘﻲ ﻓﺸﺎﺭ ﺑﺎﻻ ﻭ ﭘﺎﺋﻴﻦ   ﻛﺎﻫﺶ ﺩﻣﺎ ﻭ ﻓﺸﺎﺭ   ﺑﺎﻻ ﺭﻓﺘﻦ  ﺩﻣﺎﻱ ﺭﻭﻏﻦ ﺳﻴﺴﺘﻢ ﻭ ﺧﺮﺍﺑﻲ  ﻛﻤﭙﺮﺳﻮﺭ 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 60

 

 

 

 

 

 

 

 

 

 

 

 EEV ﺭﻭﺵ ﭼﻚ ﻛﺮﺩﻥ 

   ﺭﺍ ﺩﺭ ﺍﻭﻟﻴﻦ ﺑﺎﺭﻱ ﻛﻪ ﺑﺮﻕ ﻭﺻﻞ ﻣﻲ ﺷﻮﺩEEVﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ ﺻﺪﺍﻱ ﺑﺎﺯ ﻭ ﺑﺴﺘﻪ ﺷﺪﻥ

  ﻣﺴﺪﻭﺩ ﺑﻮﺩﻥ ﻟﻮﻟﻪ ﺩﻭﭘﻬﻨﻲ  / 

 

 

 ﺑﺎﺯ ﻛﺮﺩﻥ ﺷﻴﺮ ﺳﺮﻭﻳﺲ ﺑﺮﺳﻲ ﺷﻴﺮ ﺳﺮﻭﻳﺲ

 

E ﺑﺮﺭﺳﻲ  EV EEV ﺍﺻﻼﺡ

  ﺑﺮﺭﺳﻲ ﺷﻴﺮ  

 

 ﺍﺻﻼﺡ ﻟﻮﻟﻪ ﻛﺸﻲ ﺑﺮﺳﻲ ﻟﻮﻟﻪ ﻛﺸﻲ

61

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

ﭼﮕﻮﻧﮕﻲ ﺑﺮﺭﺳﻲ ﻣﻘﺎﻭﻣﺖ ﻓﺎﺯﻫﺎﻱ ﻛﻤﭙﺮﺳﻮﺭ 

   ﻣﻘﺎﻭﻣﺖ ﻋﺎﻳﻘﻲ ﺑﻴﻦ ﻛﻤﭙﺮﺳﻮﺭ ﻭ ﻟﻮﻟﻪ 

ﺗﻮﺟﻪ ﺩﺍﺷﺘﻪ ﺑﺎﺷﻴﺪ ﻣﺤﻞ U,V,W)ﻣﻘﺎﻭﻣﺖ ﺑﻴﻦ  ( ﺍﺯ ﺭﻭﻱ ﻛﻤﭙﺮﺳﻮﺭ ﺑﺎ ﻟﻮﻟﻪ ﻛﻤﭙﺮﺳﻮﺭ). ﺗﺴﺖ ﺭﻧﮓ ﻧﺪﺍﺷﺘﻪ ﺑﺎﺷﺪ( 

 

 

 

 

 

 

 

 

 W ﻭ V ﻭ U ﻣﻘﺎﻭﻣﺖ ﻓﺎﺯﻫﺎﻱ 

( . ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﺍﻥ 1 ﺩﺍﺯﻩ ﮔﻴﺮﻱ ﻣﻘﺎﻭﻣﺖ )ﺍﻫﻢ  ﻗﺮﺍﺭ ﺩﻫﻴﺪ   .ﻣﻘﺎﻭﻣﺖ ﻓﺎﺯﻫﺎ ﺭﺍ ﺩﻭ ﺑﻪ ﺩﻭ ﺍﻧﺪﺍﺯﻩ ﺑﮕﻴﺮﻳﺪ 2  ﺍﻫﻢ ﺑﻪ ﻣﻌﻨﻲ ﻣﻌﻴﻮﺏ ﺑﻮﺩﻥ ﻛﻤﭙﺮﺳﻮﺭ ﻣﻲ ﺑﺎﺷﺪ0 .ﻣﻘﺪﺍﺭ 3  .ﺍﮔﺮ ﻣﻘﺪﺍﺭ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ ﺑﻪ ﺻﻮﺭﺕ ﺩﻗﻴﻖ ﻣﺸﺨﺺ ﻧﺒﻮﺩ 4 ﺑﻪ ﺻﻮﺭﺕ ﺯﻳﺮ ﺩﻭﺑﺎﺭﻩ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻛﻨﻴﺪ.   .ﺍﮔﺮ ﻣﻘﺪﺍﺭ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻧﺮﻣﺎﻝ ﺑﻮﺩ ﺍﻣﻜﺎﻥ  ﻭﺟﻮﺩ ﺍﻳﺮﺍﺩ ﺩﺭ ﺳﻴﻢ 5

 

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 62

 

ﺑﻨﺪﻱ ﻫﺎ ﻣﻲ ﺑﺎﺷﺪ. 

   ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻣﻘﺎﻭﻣﺖ ﻓﺎﺯﻫﺎ ﺍﺯ ﺭﻭﻱ ﺗﺮﻣﻴﻨﺎﻝ ﻛﻤﭙﺮﺳﻮﺭ •

 

 

 

 

 

ﭼﮕﻮﻧﮕﻲ ﺑﺮﺭﺳﻲ ﺍﻳﺮﺍﺩ ﺳﻴﻢ ﺑﻨﺪﻱ ﻛﻤﭙﺮﺳﻮﺭ 

 

 

 ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ ﺁﻳﺎ ﺳﻴﻢ ﻫﺎﻱ ﺭﻭﻱ ﺑﺮﺩ ﺑﺎ ﺳﻴﻢ ﻫﺎﻱ ﺭﻭﻱ ﻛﻤﭙﺮﺳﻮﺭ ﺑﻪ ﺗﺮﺗﻴﺐ ﺭﻧﮓ ﻭ  ﺩﺭﺳﺖ ﻭﺻﻞ ﺷﺪﻩ ﺍﻧﺪ. 

  . ﺑﺮ ﺭﻭﻱ ﺗﺮﻣﻴﻨﺎﻟﻬﺎ ﻭﺻﻞ ﺑﺎﺷﻨﺪWﻭ U ,V ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ ﻛﻪ ﺳﻴﻢ ﻫﺎﻱ 

  . ﺟﻬﺖ ﺳﻴﻢ ﺑﻨﺪﻱ ﻧﺴﺒﺖ ﺑﻪ ﻧﻮﻉ ﻛﻤﭙﺮﺳﻮﺭ ﻣﺘﻔﺎﻭﺕ ﺍﺳﺖ 

 

 

)ﺯﺭﺩ (Y )ﺁﺑﻲ (B  R( )ﻗﺮﻣﺰ

63

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

 

 

 

 

 

 

 

 

 IPMﭼﮕﻮﻧﮕﻲ ﺑﺮﺭﺳﻲ ﻗﺴﻤﺖ

ﻫﺪﻑ

 

 ﺑﺮﺩ IPMﺗﺸﺨﻴﺺ ﺍﻳﺮﺍﺩ ﺍﺻﻠﻲ 

 

ﻣﻮﺍﺭﺩ ﺑﺮﺭﺳﻲ

 

ﺑﺮﺭﺳﻲ ﺍﺭﻭﺭ ﺟﺮﻳﺎﻥ 1 . ﺁﺷﻜﺎﺭﺳﺎﺯ 

 

 

  ﻣﺮﺍﺣﻞ ﺭﻭﻧﺪ ﺑﺮﺭﺳﻲ    ﺻﺒﺮ ﻛﻨﻴﺪ ﺗﺎ 1 ﺭﻭﻱ ﺑﺮﺩ ﻭﺍﺣﺪ ﺑﻴﺮﻭﻧﻲ LED )ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﺧﺎﻣﻮﺵ ﻛﻨﻴﺪ ﺧﺎﻣﻮﺵ ﺷﻮﺩ(    ﺳﻴﻢ ﻫﺎﻱ ﻛﻤﭙﺮﺳﻮﺭ ﺭﺍ ﺟﺪﺍ ﻛﻨﻴﺪ 2  ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﻣﻘﺪﺍﺭ ﺩﻳﻮﺩﻱ ﻗﺮﺍﺭ ﺩﻫﻴﺪ ﻭﻣﻘﺪﺍﺭ ﻭﻟﺘﺎژ ﺭﺍ ﻣﻄﺎﺑﻖ ﺷﻜﻞ 3 ﺯﻳﺮ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻛﻨﻴﺪ

 

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 64

 

  ﻭﻟﺖ ﺑﺎﺷﺪ0/6 ﺗﺎ 0/4  ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ ﻭﻟﺘﺎژ ﺍﺯ 4  ﺭﺍ ﺍﺯ ﻧﻈﺮ ﺍﺗﺼﺎﻟﻲ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ IPM  ﭘﺎﻳﻪ ﻫﺎﻱ 5

 

 IPM IGBT ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ 

 

 

 

 IPMﺷﻤﺎﺭﻩ ﭘﻴﻦ ﻫﺎ ﻭ ﭼﻴﺪﻣﺎﻥ ﭘﻴﻦ ﻫﺎﻱ

 

 

 

 

( IPM IGBTﭼﮕﻮﻧﮕﻲ ﺑﺮﺭﺳﻲ ﻗﺴﻤﺖ  )ﺣﺎﻟﺖ ﺩﻳﻮﺩ 

  .ﻛﺎﻧﻜﺘﻮﺭﻫﺎ ﺭﺍ ﺍﺯ ﺭﻭﻱ ﺑﺮﺩ ﺟﺪﺍ ﻛﻨﻴﺪ 1 2 .. ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺩﻳﻮﺩ ﻗﺮﺍﺭ ﺩﻫﻴﺪ . 1 ﺭﺍ ﻣﻄﺎﺑﻖ ﺷﻜﻞ  P~U/P~V/P~W .ﻭﻟﺘﺎژ ﺑﻴﻦ 3 ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻛﻨﻴﺪ . 2 ﺭﺍﻣﻄﺎﺑﻖ ﺷﻜﻞ U~Nu/V~Nu/W~Nu  .ﻭﻟﺘﺎژ ﺑﻴﻦ 4 ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻛﻨﻴﺪ

 ﺑﺮﺭﺳﻲ ﺑﺮﺍﻱ ﺍﺗﺼﺎﻟﻲ

 

 ﺩﻗﺖ ﻛﻨﻴﺪ ﭘﺮﺍﺏ ﻣﺸﻜﻲ ﻭ  ﻗﺮﻣﺰ ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺟﺎﺑﺠﺎ ﻗﺮﺍﺭ ﻧﮕﻴﺮﻧﺪ. 

 

65

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

 .ﺍﮔﺮ ﻣﻘﺪﺍﺭ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ ﺑﻪ ﺻﻮﺭﺕ ﻗﺎﺑﻞ ﻣﻼﺣﻈﻪ ﺍﻱ ﺑﺎ ﻣﻘﺪﺍﺭ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ ﺗﻔﺎﻭﺕ ﺩﺍﺷﺖ 5 IPM. ﺧﺮﺍﺏ ﺍﺳﺖ

 

 

 

 

 

 

 

 

ﻣﺪﺍﺭ ﺁﺷﻜﺎﺭ ﺳﺎﺯ ﺟﺮﻳﺎﻥ ﻓﺎﺯ ﻛﻤﭙﺮﺳﻮﺭ 

ﻫﺪﻑ ﺗﺸﺨﻴﺺ ﺍﻳﺠﺎﺩ ﺟﺮﻳﺎﻥ ﺑﺎﻻﻱ ﻛﻤﭙﺮﺳﻮﺭ ﺑﺪﻟﻴﻞ ﺍﺭﻭﺭ ﺁﺷﻜﺎﺭﺳﺎﺯ ﺟﺮﻳﺎﻥ ﻓﺎﺯ 

 

ﻣﻮﺍﺭﺩ ﺑﺮﺭﺳﻲ 

 

. ﺑﺮﺭﺳﻲ ﺍﺭﻭﺭ ﺟﺮﻳﺎﻥ 1 ﺁﺷﻜﺎﺭﺳﺎﺯ 

 

 

  ﻣﺮﺍﺣﻞ ﺗﺮﻣﻴﻨﺎﻝ  ﻧﺮﻣﺎﻝ  1  U -Nu  0.4V ~ 0.6V  2  V -Nv  0.4V ~ 0.6V  3  W -Nw  0.4V ~ 0.6V 

2ﺷﻜﻞ 2 ﺷﻜﻞ

 

  ﻣﺮﺍﺣﻞ  ﺗﺮﻣﻴﻨﺎﻝ  ﻧﺮﻣﺎﻝ 0.4V ~ 0.6V  P-U  1  0.4V ~ 0.6V  P-V  2  0.4V ~ 0.6V  P-W  3 

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 66

 

ﺭﻭﺵ ﺑﺮﺭﺳﻲ 

 

 

 

 

 

 

 

 

 

 

 

 

 

ﺗﻮﺟﻪ !

 ﺩﻗﺖ ﻛﻨﻴﺪ ﺭﻧﺞ ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺩﺭﺳﺖ ،ﻭﻗﺘﻲ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻣﻴﻜﻨﻴﺪ ﻭ ﺑﺮﻕ ﺑﻪ ﺩﺳﺘﮕﺎﻩ ﻭﺻﻞ ﺍﺳﺖ ﺍﻧﺘﺨﺎﺏ ﺷﺪﻩ ﺑﺎﺷﺪ . ﻭ ﻣﻮﺍﻇﺐ ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﺑﺎ ﺩﻳﮕﺮ ﻗﺴﻤﺖ ﻫﺎﻱ ﺑﺮﺩ ﺑﺎﺷﻴﺪ 

  ﮔﺬﺍﺷﺘﻪ ﻭ ﺟﺮﻳﺎﻥ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪDC - ﺭﻧﺞ ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﻭﻟﺘﺎژ 1  ﺍﻧﺪﺍﺯﻩ ﺑﮕﻴﺮﻳﺪGND ﺭﺍﺑﺎ U ,V,W - ﻭﻟﺘﺎژ 2  ﻭﻟﺖ ﻣﻲ ﺑﺎﺷﺪ2/5 ±0/5 - ﻣﻘﺪﺍﺭ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ 3  - ﺩﺭ ﺻﻮﺭﺕ ﺩﺭﺳﺖ ﻧﺒﻮﺩﻥ ﻭﻟﺘﺎژ ﺑﺮﺩ ﺭﺍ ﺗﻌﻮﻳﺾ ﻛﻨﻴﺪ 4

 ﺑﺮﻕ ﺭﺍ ﻭﺻﻞ ﻛﻨﻴﺪ

ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ ﺭﺍ ﺧﺎﻣﻮﺵ  ﻛﻨﻴﺪ

 ﻭﻟﺘﺎژ ﺭﺍ ﺍﻧﺪﺍﺯﻩ ﺑﮕﻴﺮﻳﺪ

ﺑﺮﺩ ﺭﺍ ﺗﻌﻮﻳﺾ  ﻛﻨﻴﺪ

ﺁﺷﻜﺎﺭ ﺳﺎﺯ ﺟﺮﻳﺎﻥ   ﻧﺮﻣﺎﻝ ﺍﺳﺖ

 ﻭﻟﺖ2/7 ﺍﻟﻲ 2/3 ﺑﻴﻦ

 

67

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

 

ﻣﺪﺍﺭ ﺁﺷﻜﺎﺭ ﺳﺎﺯ ﺟﺮﻳﺎﻥ ﻭﺭﻭﺩﻱ 

ﻫﺪﻑ ﺗﺸﺨﻴﺺ ﺍﻳﺠﺎﺩ ﺟﺮﻳﺎﻥ ﺑﺎﻻﻱ ﻛﻤﭙﺮﺳﻮﺭ ﺑﺪﻟﻴﻞ ﺍﺭﻭﺭ ﺁﺷﻜﺎﺭﺳﺎﺯ ﺟﺮﻳﺎﻥ ﻓﺎﺯ 

 

ﻣﻮﺍﺭﺩ ﺑﺮﺭﺳﻲ 

 

. ﺑﺮﺭﺳﻲ ﺍﺭﻭﺭ ﺟﺮﻳﺎﻥ 1 ﺁﺷﻜﺎﺭﺳﺎﺯ 

 

ﺭﻭﺵ ﺑﺮﺭﺳﻲ 

 

 

 

 

 

 

 

 

 ﺑﺮﻕ ﺭﺍ ﻭﺻﻞ ﻛﻨﻴﺪ

 ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ ﺭﺍ ﺧﺎﻣﻮﺵ ﻛﻨﻴﺪ

 ﻭﻟﺘﺎژ ﺭﺍ ﺍﻧﺪﺍﺯﻩ ﺑﮕﻴﺮﻳﺪ

ﺑﺮﺩ ﺭﺍ ﺗﻌﻮﻳﺾ  ﻛﻨﻴﺪ

ﺁﺷﻜﺎﺭ ﺳﺎﺯ ﺟﺮﻳﺎﻥ   ﻧﺮﻣﺎﻝ ﺍﺳﺖ

 ﻭﻟﺖ2/7 ﺍﻟﻲ 2/3 ﺑﻴﻦ

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 68

 

ﺗﻮﺟﻪ !

ﻭﻗﺘﻲ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻣﻴﻜﻨﻴﺪ ﻭ ﺑﺮﻕ ﺑﻪ ﺩﺳﺘﮕﺎﻩ ﻭﺻﻞ ﺍﺳﺖ, ﺩﻗﺖ ﻛﻨﻴﺪ ﺭﻧﺞ ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺩﺭﺳﺖ ﺍﻧﺘﺨﺎﺏ ﺷﺪﻩ ﺑﺎﺷﺪ . ﻭ ﻣﻮﺍﻇﺐ ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ ﺑﺎ ﺩﻳﮕﺮ ﻗﺴﻤﺖ ﻫﺎﻱ ﺑﺮﺩ ﺑﺎﺷﻴﺪ 

ﺭﻧﺞ ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﻭﻟﺘﺎژ 1  ﮔﺬﺍﺷﺘﻪ ﻭ ﺟﺮﻳﺎﻥ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪDC ﺟﺮﻳﺎﻥ ﺑﻴﻦ 2 . Micom _GND ﻭ Input _I  ﺭﺍﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ ﻣﻘﺪﺍﺭ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ 3  ﻭﻟﺖ ﻣﻲ ﺑﺎﺷﺪ2/5 ±0/5 ﺩﺭ ﺻﻮﺭﺕ ﺩﺭﺳﺖ ﻧﺒﻮﺩﻥ ﻭﻟﺘﺎژ ﺑﺮﺩ ﺭﺍ ﺗﻌﻮﻳﺾ ﻛﻨﻴﺪ 4 - 

 

) 4ﭼﮕﻮﻧﮕﻲ ﺑﺮﺭﺳﻲ ﺷﻴﺮ   (4 Way Valve ﻃﺮﻓﻪ

ﻫﺪﻑ 

 

ﺗﺸﺨﻲﺹ ﺍﻳﺮﺍﺩ ﺷﻴﺮ    ﻃﺮﻓﻪ4

 

ﻣﻮﺍﺭﺩ ﺑﺮﺭﺳﻲ 

 

ﺑﺮﺭﺳﻲ  ﻭﻟﺘﺎژ ﻛﺎﻧﻜﺘﻮﺭ ﺷﻴﺮ 1 ﻃﺮﻓﻪ ﺍﺯ 4 . ﺭﻭﻱ ﺑﺮﺩ ﺑﺮﺭﺳﻲ ﻣﻘﺎﻭﻣﺖ ﻛﻮﻳﻞ ﺷﻴﺮ 2   ﻃﺮﻓﻪ4

 

 

   ﻃﺮﻓﻪ4 ﺑﺮﺭﺳﻲ ﻭﻟﺘﺎژ ﺧﺮﻭﺟﻲ ﻛﺎﻧﻜﺘﻮﺭ ﺷﻴﺮ 

 ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻭﻟﺘﺎژ 1  ﺑﮕﺬﺍﺭﻳﺪ AC .

69

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

 ﻭﻟﺘﺎژ ﺧﺮﻭﺟﻲ ﺍﺯ ﻛﺎﻧﻜﺘﻮﺭ ﺷﻴﺮ 2 .  ﺭﺍﻫﻪ ﺍﺯ ﺭﻭﻱ ﺑﺮﺩ ﺭﺍ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻛﻨﻴﺪ4 .

 ﻭﻟﺘﺎژ ﻧﺮﻣﺎﻝ 3 .  ﺩﺭﺻﺪ ﻣﻲ ﺑﺎﺷﺪ10 ﻭﻟﺖ ﺑﺎ ﺗﻠﺮﺍﻧﺲ 220 .

 4. .ﺍﮔﺮ ﻣﻘﺪﺍﺭ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ ﺑﺎ ﻣﻘﺪﺍﺭ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ ﻣﺘﻔﺎﻭﺕ ﺑﻮﺩ ﺑﺮﺩ ﺭﺍ ﺗﻌﻮﻳﺾ ﻛﻨﻴﺪ 

 

 

 

 ﺑﻌﺪ ﺍﺯ ﻛﺎﺭﻛﺮﺩ Standby ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺑﺎﻳﺪ ﺩﺭ ﺷﺮﻭﻉ ﺣﺎﻟﺖ ﮔﺮﻣﺎﻳﺶ ﺑﺎﺷﺪ ﻭ ﺩﺭ ﺯﻣﺎﻥ ﺩﺳﺘﮕﺎﻩ ﺑﺎﺷﺪ.

   ﻃﺮﻓﻪ4 ﺑﺮﺭﺳﻲ ﻣﻘﺎﻭﻣﺖ ﻛﻮﻳﻞ ﺷﻴﺮ 

1 .. ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻣﻘﺎﻭﻣﺖ ﻗﺮﺍﺭ ﺩﻫﻴﺪ . 4 .ﻣﻘﺎﻭﻣﺖ ﺩﻭ ﺳﺮ ﺍﺯ ﺳﻮﻛﺖ ﺷﻴﺮ 2 ﺭﺍﻫﻪ ﺭﺍ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻛﻨﻴﺪ 1.4K . ﻣﻘﺪﺍﺭ ﻣﻘﺎﻭﻣﺖ  ﺍﺳﺘﺎﻧﺪﺍﺭﺩ 3 Ω±10%. ﺍﺳﺖ 4. . ﺍﮔﺮ ﻣﻘﺪﺍﺭ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ ﺑﺎ ﻣﻘﺪﺍﺭ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ ﺗﻔﺎﻭﺕ ﺩﺍﺷﺖ ﻛﻮﻳﻞ ﺭﺍ ﺗﻌﻮﻳﺾ ﻛﻨﻴﺪ 

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 70

 

 

 

 EEVﭼﮕﻮﻧﮕﻲ ﺑﺮﺭﺳﻲ ﺷﻴﺮ

ﻫﺪﻑ 

 

 EEVﺗﺸﺨﻴﺺ ﺍﻳﺮﺍﺩ

 

ﻣﻮﺍﺭﺩ ﺑﺮﺭﺳﻲ 

 

ﺑﺮﺭﺳﻲ ﻣﻘﺎﻭﻣﺖ ﺷﻴﺮ 1 .EEV 

 

 

 EEV ﺑﺮﺭﺳﻲ ﻣﻘﺎﻭﻣﺖ ﺷﻴﺮ 

 

 

71

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

 

  .ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻣﻘﺎﻭﻣﺖ ﻗﺮﺍﺭ ﺩﻫﻴﺪ 1  .ﻣﻘﺎﻭﻣﺖ ﺑﻴﻦ ﭘﺎﻳﻪ ﻫﺎ ﺭﺍ ﺍﻧﺪﺍﺯﻩ ﺑﮕﻴﺮﻳﺪ 2 3 .. ﺑﺮﺍﻱ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻭ ﻣﻘﺎﺩﻳﺮ ﺍﺳﺘﺎﻧﺪﺍﺭﺩ ﺍﺯ ﺟﺪﻭﻝ ﺯﻳﺮ ﭘﻴﺮﻭﻱ ﻛﻨﻴﺪ 

ﺷﻤﺎﺭﻩ ﭘﺎﻳﻪ ﻫﺎ  ﻣﻘﺪﺍﺭ ﻧﺮﻣﺎﻝ  1-4 45 Ω±5Ω  1-6 45 Ω±5Ω  2-3 45 Ω±5Ω  2-5 45 Ω±5Ω 

 

. EEV ﻣﻘﺪﺍﺭ ﻣﻘﺎﻭﻣﺖ ﻛﻮﻳﻞ  ﺩﺭ ﻣﺪﻝ ﻫﺎﻱ ﻣﺨﺘﻠﻒ  ﻣﺘﻔﺎﻭﺕ ﻣﻲ ﺑﺎﺷﺪ 

 

 

 

 

 

 

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 72

 

ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ ﻣﺪﻝ ﻫﺎﻱ ﺗﺎﻳﺘﺎﻥ )ﺩﻭﺭ ﺛﺎﺑﺖ(

 

ﻛﺪ ﺧﻄﺎ ﻫﺎ ﻭ ﺗﻮﺿﻴﺤﺎﺕ ﺁﻧﻬﺎ      ﻧﺸﺎﻧﮕﺮ ﻛﺪ ﺧﻄﺎ •. ﺍﻳﻦ ﻋﻤﻠﻜﺮﺩ ﺑﺮﺍﻱ ﺗﺸﺨﻴﺺ ﺍﻳﺮﺍﺩ ﻭ ﻧﺸﺎﻥ ﺩﺍﺩﻥ ﺁﻥ ﺩﺭ ﺻﻔﺤﻪ ﺩﻳﺴﭙﻠﻲ ﻣﻲ ﺑﺎﺷﺪ •. ﺍﮔﺮ ﻫﻤﺰﻣﺎﻥ ﺩﻭ ﺧﻄﺎ ﺩﺍﺷﺘﻪ ﺑﺎﺷﻴﻢ ﺩﺭ ﺍﺑﺘﺪﺍ ﺧﻄﺎﻳﻲ ﻛﻪ ﺧﻄﺮﻧﺎﻙ ﺗﺮ ﺍﺳﺖ ﻧﻤﺎﻳﺶ ﺩﺍﺩﻩ ﻣﻲ ﺷﻮﺩ L ﺑﻌﺪ ﺍﺯ ﻭﻗﻮﻉ ﺧﻄﺎ ﺍﮔﺮ ﺍﻳﺮﺍﺩ ﺭﻓﻊ ﮔﺮﺩﺩ• ED. ﺑﻪ ﺻﻮﺭﺕ ﻧﺮﻣﺎﻝ ﺷﺮﻭﻉ ﺑﻪ ﭼﺸﻤﻚ ﺯﺩﻥ ﻣﻲ ﻛﻨﺪ •. ﭘﺲ ﺍﺯ ﺑﺮﻃﺮﻑ ﻛﺮﺩﻥ ﺧﻄﺎ، ﺑﺮﻕ ﺭﺍ ﻗﻄﻊ ﻭ ﺳﭙﺲ ﺩﻭﺑﺎﺭﻩ ﻭﺻﻞ ﻛﻨﻴﺪ    ﺗﻮﺿﻴﺤﺎﺕ ﺧﻄﺎ ﺩﺭ ﻭﺍﺣﺪ ﺩﺍﺧﻠﻲ  - 

 

ﻛﺪ ﺧﻄﺎ 

ﺗﻮﺿﻴﺤﺎﺕ

ﻧﺸﺎﻧﻪ ﺧﻄﺎ  ﻭﺍﺣﺪ ﺩﺍﺧﻠﻲ LED1(  )ﺳﺒﺰ LED2 )ﻗﺮﻣﺰ( 

 1 ﺳﻨﺴﻮﺭ ﻫﻮﺍﻱ ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ ﺑﺎﺯ  /ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ 

   ﺑﺎﺭ1

 

 2 /ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ ﻭﺭﻭﺩﻱ ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ ﺑﺎﺯ ﺍﺗﺼﺎﻝ ﻛﻮﺗﺎﻩ 

   ﺑﺎﺭ2

 

6 EEPROM   ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ 6 - ﺑﺎﺭ 

 

9 EEPROM   ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ 9 - ﺑﺎﺭ 

 

 

 

 

 

 

73

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

 

SB/SC Chassis (Titan) 

 

 

   ﺧﻄﺎﻫﺎﻱ ﻭﺍﺣﺪ ﺩﺍﺧﻠﻲ–ﺭﻓﻊ ﺍﻳﺮﺍﺩ  CH01, CH02, CH06,CH12ﺧﻄﺎﻫﺎﻱ

 

ﻋﻠﺖ ﺧﻄﺎ ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ ﻋﻨﻮﺍﻥ ﻛﺪ ﺧﻄﺎ

 ﻭﺿﻌﻴﺖ ﺍﺗﺼﺎﻝ ﺳﻨﺴﻮﺭ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ  : 10 ﻣﻘﺎﻭﻣﺖ ﻧﺮﻣﺎﻝ ㏀ /at 25℃(77℉)  ﺍﺗﺼﺎﻝ ﻧﺎﺩﺭﺳﺖ ﻳﺎ ﺑﺎﺯ  /ﺍﺗﺼﺎﻝ  ﻛﻮﺗﺎﻩ ﺑﻮﺩﻥ ﺳﻨﺴﻮﺭ  ﺳﻨﺴﻮﺭ ﻫﻮﺍﻱ ﺩﺍﺧﻠﻲ  ﻳﻚ ﺑﺎﺭ 1 ) ﭼﺸﻤﻚ (  ﻭﺿﻌﻴﺖ ﺍﺗﺼﺎﻝ ﺳﻨﺴﻮﺭ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ  : 5 ﻣﻘﺎﻭﻣﺖ ﻧﺮﻣﺎﻝ ㏀ /at 25℃(77℉)   ﺍﺗﺼﺎﻝ ﻧﺎﺩﺭﺳﺖ ﻳﺎ ﺑﺎﺯ  /ﺍﺗﺼﺎﻝ  ﻛﻮﺗﺎﻩ ﺑﻮﺩﻥ ﺳﻨﺴﻮﺭ  ﺳﻨﺴﻮﺭ ﻟﻮﻟﻪ ﻭﺭﻭﺩﻱ ﻳﻮﻧﻴﺖ ﺩﺍﺧﻠﻲ  ﺩﻭ ﺑﺎﺭ 2 ) ﭼﺸﻤﻚ(     ﻭﺿﻌﻴﺖ ﺍﺗﺼﺎﻝ ﺳﻨﺴﻮﺭ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ 1 -.  ﺑﻌﺪ ﺍﺯ ﺟﺪﺍ ﻛﺮﺩﻥ ﺳﻨﺴﻮﺭ ﺍﺯ ﺑﺮﺩ ﻣﻘﺎﻭﻣﺖ ﺁﻥ ﺭﺍ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻛﻨﻴﺪ 2 -. 

  ﻳﻜﺎﻥcoolingﭼﺮﺍﻍ   ﺩﻫﮕﺎﻥHeatingﭼﺮﺍﻍ

  ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ 74

 

ﺍﮔﺮ ﻣﻘﺎﻭﻣﺖ 3 . ﻳﺎ ﺑﻴﻨﻬﺎﻳﺖ ﺑﻮﺩ ﺳﻨﺴﻮﺭ ﺭﺍ ﺗﻌﻮﻳﺾ ﻛﻨﻴﺪ0 ﺍﮔﺮ ﻣﻘﺎﻭﻣﺖ ﻧﺮﻣﺎﻝ ﺑﻮﺩ ﺧﺮﺍﺑﻲ ﺑﺮﺩ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ 4 -. ﻣﺤﻞ ﻗﺮﺍﺭﮔﻴﺮﻱ ﺳﻨﺴﻮﺭﻫﺎ

 

 

 

 

 

 

 

 

 

 

 

 

 ﻟﻮﻟﻪ ﻣﺎﻳﻊ ﻟﻮﻟﻪ ﮔﺎﺯ ﺍﻭﺍﭘﺮﺍﺗﻮﺭ

ﺭﻭﺵ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ :  . .ﻛﺎﻧﻜﺘﻮﺭ ﺭﺍ ﺍﺯ ﺭﻭﻱ ﺑﺮﺩ ﺟﺪﺍ ﻛﻨﻴﺪ1 . ﻗﺮﺍﺭ ﺩﻫﻴﺪΩ .ﺭﻧﺞ ﻣﻮﻟﺘﻲ ﻣﺘﺮ ﺭﺍ ﺭﻭﻱ ﺍﻫﻢ 2  . .ﻣﻘﺎﻭﻣﺖ ﻛﺎﻧﻜﺘﻮﺭ ﺭﺍ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻛﻨﻴﺪ 3

 

 

 ﻛﺎﻧﻜﺘﻮﺭ ﺳﻨﺴﻮﺭ

 ﺍﻫﻢ ﻣﺘﺮ

75

 

 ﺭﺍﻫﻨﻤﺎﻱ ﻋﻴﺐ ﻳﺎﺑﻲ

CH09 ﺧﻄﺎﻱ -CH06( )ﺧﻄﺎﻱ ﺑﺮﺩ ﺁﭘﺸﻦ 

 

ﻋﻠﺖ ﺧﻄﺎ ﻧﻘﺎﻁ ﺑﺮﺭﺳﻲ ﻋﻨﻮﺍﻥ ﻛﺪ ﺧﻄﺎ

 

ﻭﺿﻌﻴﺖ ﺍﺗﺼﺎﻝ ﺑﺮﺩ ﺁﭘﺸﻦ ﺭﺍ ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ

ﺍﺗﺼﺎﻝ ﻧﺎﺩﺭﺳﺖ ﺑﺮﺩ ﺁﭘﺸﻦ ﻳﺎ  ﺍﻳﺮﺍﺩ ﺍﺯ ﺑﺮﺩ ﺁﭘﺸﻦ

ﺧﻄﺎﻱ ﺑﺮﺩ ﺁﭘﺸﻦ

 ﺑﺎ 9 ﻳﺎ 6 ﭼﺸﻤﻚ ﺯﺩﻥ

 

ﺑﺮﺭﺳﻲ ﻛﻨﻴﺪ ﺑﺮﺩ ﺁﭘﺸﻦ ﺑﻪ ﺩﺭﺳﺘﻲ ﺍﺗﺼﺎﻝ ﺩﺍﺷﺘﻪ ﺑﺎﺷﺪ 1 . 

 

 

  ﻫﺎ ﺑﻪ ﺻﻮﺭﺕ ﻧﺎ ﻣﻔﻬﻮﻡ ﭼﺸﻤﻚ ﻣﻲ ﺯﻧﻨﺪ ﻋﻠﺖ ﺍﻳﻦ ﺍﻳﺮﺍﺩ ﻣﻤﻜﻦLED ﺩﺭ ﺑﺮﺧﻲ ﻣﻮﺍﺭﺩ ﺩﻳﺪﻩ ﺷﺪﻩ ﻛﻪ ۞ ﺍﺳﺖ ﺑﺮﺩ ﺩﻳﺴﭙﻠﻲ ﻳﺎ ﺑﺮﺩ ﺁﭘﺸﻦ ﺑﺎﺷﺪ ﻛﻪ ﺣﺘﻤﺎ ﺑﻌﺪ ﺍﺯ ﺗﻌﻮﻳﺾ ﺍﻳﻦ ﻗﻄﻌﺎﺕ ﺑﺎﻳﺪ ﺑﺮﻕ ﺩﺳﺘﮕﺎﻩ ﺭﺍ ﺭﻳﺴﺖ ﻛﻨﻴﺪ . 

 

 ﻣﻴﺰﻧﺪ09ﻭﺑﺮﺧﻲ ﺍﺭﻭﺭ 06 ﺗﻮﺟﻪ:ﺩﺭ ﺩﺳﺘﮕﺎﻫﻬﺎﻱ ﺗﺎﻳﺘﺎﻥ ﺩﺭﻫﻨﮕﺎﻡ ﺍﻳﺮﺍﺩ ﺑﺮﺩ ﺁﺑﺸﻦ، ﺍﺭﻭﺭ ﮔﺎﻫﻲ ﺍﻭﻗﺎﺕ ﺑﻪ ﻣﺤﺾ ﺍﺗﺼﺎﻝ ﺑﺮﻕ ﺩﺳﺘﮕﺎﻩ ﻓﻴﻮﺯ ﺭﻭﻱ ﺑﺮﺩ ﻣﻲ ﺳﻮﺯﺩ ﻋﻠﺖ ﺩﺭ ﺍﻳﻦ ﻣﻮﺍﻗﻊ ﺍﺯ ﺍﺗﺼﺎﻟﻲ

درباره میهن تهویه

گروه فنی میهن تهویه با تکیه بر نیروهای متخصص در زمینه طراحی/فروش/تعمیر و پشتیبانی سیستم‌های گرمایشی/سرمایشی ساختمان فعالیت می‌کند. مسئولیت‌پذیری و جدیت در کار همواره شعار و باور اصلی این مجموعه در ارائه خدمات صنعتی بوده است.

 

تعمیرات تخصصی کولرگازی، داکت اسپیلت، چیلر،  مینی چیلر، سردخانه، موتورخانه، پکیج شوفاژ دیواری، آبسردکنهای اداری

شماره‌ تماس دفتر:   02126853146

تماس فوری (رضایی) :   09120206031

مشاوره تماس (تلگرام):  09366941897

نشانی دفتر مرکزی: تهران - سعادت آباد - ایثارگران شمالی - خیابان امام‌زاده داوود